Chapter 4
108
Kaba Ilco Lodging Access Control System
Expiry:
From 1 to 4 hours, or until the card is used once, whichever is first.
Factory default expiry:
1 hour
Parameters: Room
number
Options: None
Notes:
A one-shot keycard for Guest Common Areas or Common Door Suites
cannot
be
made.
A.3 Adjoining Suite
Purpose:
Opens each door of a combination of up to 15 individual guest rooms, within a 15
room number range. No resetting of the individual door locks is required.
Example:
Possible Not
Possible*
Not
Possible**
106 101 116
107 122 117
108 123 118
114
*Rooms not within a 15-room number range.
See “Convention Suite Keycard”
** Rooms belong to a Common Door Suite.
Minimum keycard:
Front Desk Authorization
Shortcut: Swipe
authorized keycard, press 1 and 2.
Expiry: From
1
hour to 2730 nights
Factory default expiry:
1 night
Parameters: Main
Room
Expiry Hour
Add Room
New/Duplicate
Nights
Number of cards
Options: Guest
Common
Areas
Salesman's Lockout
Folio Number
Notes:
Enter all the room numbers using the up <
S
> or down <
T
> arrows and set
the
desired rooms to YES using the left <
W
> or right <
X
> arrows. After entering
the
last room number in the suite, press < > to continue.
Cannot include doors of a Common Door Suite