Chapter 5
150
Kaba Ilco Lodging Access Control System
Equipment required:
FDU
Lock communication cable
Initialization keycard
Programming keycard
Completed Planning Forms
Minimum keycard required:
Programming
Authorization
Steps to program the Restricted Area lock addresses:
1.
If this is a first time installation, or if power to the lock has been interrupted,
insert the Initialization keycard in the lock. The red and green indicators
should light, then only the green indicator should flash. Re-insert the
Initialization keycard if the pattern of indicator lights described is not
observed.
2.
Swipe a keycard or enter a PIN value having a Programming authorized
user level.
3.
Press 8 or use the down <
T
> arrow followed by < > to reach the
“Programming FDU/Lock” menu.
4.
Press 1 or < > to reach the “Lock Programming” menu.
5.
Press 5 or use the down <
T
> arrow followed by < > to reach the
“Programming Restricted Areas” menu.
NOTE:
The initialization
keycard starts up the
PCB. It does not
prepare the board for
programming
Summary of Contents for ILCO FDU
Page 1: ...PK3514_06_07 USER S GUIDE Next Generation FDU ...
Page 3: ...ii Kaba Ilco Lodging Access Control System ...
Page 10: ...ix Kaba Ilco Lodging Access Control System ...
Page 11: ......
Page 243: ......
Page 245: ......
Page 258: ......
Page 260: ......
Page 269: ......