Maintenance and Troubleshooting
Kaba Ilco Lodging Access Control System
219
Problem:
6)
The lock flashes both a red and a green light when a staff keycard is used.
Possible causes:
x
The batteries are getting low.
Solutions:
x
Change the batteries. Follow the instructions in
Section 11.4 – Replacing a
Bettery
.
Problem:
7)
The lock cannot communicate with the Front Desk Unit.
Possible causes:
x
A Programming keycard has not been inserted into the lock prior to the insertion
of the infrared communication adapter.
x
30 seconds have elapsed since the Programming keycard was inserted in the
lock.
Solutions:
x
In the case of a battery change, insert the Initialization keycard, then the
Programming keycard, followed by the infrared communication adapter.
x
The FDU/lock communication must be started within 30 seconds of inserting the
Programming keycard in the lock.
Problem:
8)
The Front Desk Unit does not accept an Authorization keycard.
Possible causes:
x
If no Authorization keycards are accepted, the magnetic heads of the FDU may
be dirty.
x
The Authorization keycard may have been cancelled.
Solutions:
x
Use a cleaning card to clean the heads of the FDU. Issue a new Authorization
keycard of the same number as the cancelled one. Ensure that this Authorization
keycard is passed through each FDU so that the previous one is cancelled.
6
7
8