PROGRAM THE E-760/770/790 LOCK
PK2915-T 07_2014 E-760/770/790 SERIES RETROFIT INSTALLATION GUIDE
Page 10
After retrofitting a door with an E-760/770/790 lock, transfer the security information from a neighbouring lock to the new lock by using the
Reset Addresses
function (see Reference Manual).
Resetting the addresses will ensure that all past lost and stolen keycards remain cancelled in the new lock,
and will set the addresses for the Section, Floor, Group, Zone and Area sub-master level so that staff keycards in use at the property will
have the same pattern of access to the door as before the retrofit. This step makes the retrofit transparent, so that the lock accepts and
rejects the same keycards as before.
Use the System 700 communication cable when reading the information from a System 700 lock, and the new E-760/770/790 com-
munication cable when communicating with an E-760/770/790 lock.
8 •
OPERATING THE ELECTRONIC OVERRIDE
If the lock will not repond to any keycard (including the Emergency keycard), there are three op-
tions that should be attempted to open the door. In order, they are:
1. Verify the batteries, and replace them if they are providing less than 4 Volts total. Insert the
Initialization keycard in the lock, then use the Emergency keycard.
2. Use the electronic override feature (requires FDU and communication cable).
3. Contact Technical Support for instructions on using the drill point.
1
Electronic Override Using the FDU
If the card reader fails, the E-760/770/790 lock can be opened using
the FDU (Front Desk Unit). The lock must have been initialized by a valid
FDU from the hotel where it is installed (i.e. with the correct internal and
external hotel codes), before the electronic override can be used.
There are two possible security levels:
Low security:
IF an FDU with a software version lower than 6.5 over-
rides the lock, the lock audit records only the date and time.
High security:
IF an FDU with version 6.5 or higher software overrides
the lock, the lock audit records the FDU number, the Authorization keycard
number, the date and the time.
Hardware Required:
Front Desk Unit (FDU), FDU to lock communication cable
Minimum Authorization Keycard Required:
Programming Authorization (PA)
When planning to retrofit a large number of doors, always ensure that each group of doors
that shares the same pattern of sub-master levels has at least one functional lock from which
to retrieve the information. Once the first E-760/770/790 lock in the group has received its
programming, the source lock can be retrofitted, and the remaining E-760/770/790 locks can be
programmed using the information from the first E-760/770/790 lock.
Front Desk Unit (FDU)
Lock communication cable
Door Lock
Magnetic E-760 Series
Locking Devices
Programming
Modules and Cables
Front Desk Unit (FDU)
Property Management System (PMS)
For E-760 Series Lock
Exit Device
Operator Model 730
For emote ccess ontroller
Front Desk
nit (FD )
Front Desk nit (FD )
M S ipe eader
emote ccess ontroller (
)
Elevator ontroller
arage Door ontroller
Standard Door it
- Magnetic Lock
- Electric Strike
or