Standalone operation with firmware option E300 V4
64
k4evo707en-2012-07
7.2.2.2 Operation as electric strike with s-module
The S-module functionality with which you will be familiar from c-lever is provided on the Compact
Reader as standard and can be parameterized using Kaba evolo Manager or Kaba exos system
software.
For more information, refer to the c-lever s-module system description (configuration).
7.2.2.3 Function of s-module
The s-module is used to override the access function by means of an external, insulated switch. It is
equipped with a
self-learning function
. During initialization (INI reset), the s-module interprets the
current switch position as the output position. If this position is changed, the action defined under
"activation" is performed. It is possible, therefore, to use a make or break contact.
Explanation of activation
Function
Meaning
As long as input
is active
As long as switch is closed
For a limited
period
With pulse active during specified time
(switched on for)
Pulse operating
mode
Each pulse changes the activation status
Explanation of actuator behavior:
Function Meaning
Always open
Always open, irrespective of mode
Open with media
Can be opened with every media (writes UID of the media to
traceback)
Always closed
Always closed, access not possible (for c-lever, emergency
opening with key)
Open with authorized media
Can be opened with authorized media