Enable a Specific User ID

This operation allows the Master User or Manager User to enable access to the
lock for a specific Access or Service User.

Step

Detailed Instructions

1.

Power lock.

Power the lock by depressing the outside lever. 

2.

Enter Master User

Enter the Master User or Manager User combina-  

or Manager User

tion. The lock will beep/flash the green LED on  

combination

each keystroke entered. If the 

Clear key is pressed

during data entry, the lock responds with one beep/
flash of the green LED followed by the red LED, and
all digits of the combination must be re-entered. The
lock responds with three beeps/flashes of the green
LED to indicate available entry. If the combination is
not valid, the lock responds with three beeps/flashes
of the red LED.

3.

Press      then 71.

Before re-lock time expires, press       (Enter key) 
followed by the 

key and then the key. The lock 

responds with two beeps/flashes of the green LED.

4.

Enter User ID.

Enter the User ID to be enabled. The lock responds
with two beeps/flashes of the green LED.

The selected User ID is enabled. 

5.

Repeat Step 4 to

Repeat Step 4 to enable additional User IDs or go  

enable additional 

to Step 6.

User IDs or go to
Step 6.

6.

Press      to exit.

Press       (Enter key) to exit this procedure. The 
lock responds with two simultaneous beeps/ flashes
of the green and red LEDs and exits the procedure.

22

Disable a Specific User ID

This operation allows the Master User or Manager User to restrict access to the
lock for a specific Access or Service User.

Note: The Master User and Manager User cannot be disabled.

Step

Detailed Instructions

1.

Power lock.

Power the lock by depressing the outside lever. 

2.

Enter Master User

Enter the Master User or Manager User combina-  

or Manager User

tion. The lock will beep/flash the green LED on  

combination

each keystroke entered. If the 

Clear key is pressed

during data entry, the lock responds with one beep/
flash of the green LED followed by the red LED, and
all digits of the combination must be re-entered. The
lock responds with three beeps/flashes of the green
LED to indicate available entry. If the combination is
not valid, the lock responds with three beeps/flashes
of the red LED.

3.

Press      then 70.

Before re-lock time expires, press       (Enter key) 
followed by the 

key and then the key. The lock 

responds with two beeps/flashes of the green 
LED.

4.

Enter User ID.

Enter the User ID to be disabled. The lock responds
with two beeps/flashes of the green LED.

The selected User ID is disabled.

5.

Repeat Step 4 to

Repeat Step 4 to disable additional User IDs or

disable additional 

go to Step 6.

User IDs or go to
Step 6.

6.

Press      to exit.

Press       (Enter key) to exit this procedure. The 
lock responds with two simultaneous beeps/
flashes of the green and red LEDs and exits the 
procedure.

Summary of Contents for PowerLever 15 Series

Page 1: ...s Control 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 Fax 800 346 9640 336 725 3269 www kaba ilco com Document Number 474 052 1105 Operating Instructions S e r i e s M...

Page 2: ...major assemblies Outside cover assembly includes a keypad for entry of control data a pair of LEDs red and green for visual feedback a beeper for audio feed back and the outside lever with a return o...

Page 3: ...de audio and visual cues to the user when lock power drops below a sufficient level for operation The lock will continually beep and flash the red LED prompting the user to depress the outside lever t...

Page 4: ...x lock The combination can consist of as little as a one digit User ID or the length can be up to six digits in length and consist of a User ID followed by a Personal Identifier Number PIN Regardless...

Page 5: ...Function will change the state of the Model 15xx lock from locked to unlocked When programmed to the unlocked or Passage func tion no combination or key override is required for entry Only managerial...

Page 6: ...limit is the maximum number of consecutive failed entry attempts that can occur before the lock temporarily shuts down to prevent combination tampering The wrong try limit is programmable from 3 9 wi...

Page 7: ...beep flashes of the red and green LEDs Note If a lock has been Activated and then Shelved the lock returns to a state where it can be opened with the default Master User combination of all 0 s The len...

Page 8: ...on User ID only otherwise Combination User ID PIN 12 Change User ID and PIN Lengths The length of the User ID the length of the PIN the length of the combina tion A User ID is mandatory and can vary b...

Page 9: ...verification If the combination was verified suc again cessfully the lock responds with two simultaneous beeps flashes of the green and red LEDs The lock responds with two beeps flashes of the red LE...

Page 10: ...Note If at any time during the procedure the lock power drops below a sufficient level for operation the lock will continually beep and flash the red LED prompting the user to depress the outside leve...

Page 11: ...the combination to open the lock The lock combination will beep flash the green LED on each keystroke entered If the Clear key is pressed during data entry the lock responds with one beep flash of the...

Page 12: ...key is pressed dur ing data entry the lock responds with one beep flash of the green LED followed by the red LED and all digits of the combination must be re entered The lock responds with three beep...

Page 13: ...ous beeps flashes of the green and red LEDs and exits the procedure 22 Disable a Specific User ID This operation allows the Master User or Manager User to restrict access to the lock for a specific Ac...

Page 14: ...nd exits this procedure 24 Disable a Group of User IDs This operation allows the Master User or Manager User to restrict access to an entire user ID group See User ID Groups page 5 for more informatio...

Page 15: ...ltaneous beeps flashes of the green and red LEDs The Manager User is now deactivated 26 Switch Passage Function On Off This operation allows Passage Function to be toggled On and Off Step Detailed Ins...

Page 16: ...l 0 s 28 Change Master User Combination Note The new User ID that is selected must be an available ID one that has not already been selected for another user Step Detailed Instructions 1 Power lock Po...

Page 17: ...___ User ID ___ PIN ______ User ID ___ PIN ______ User ID ___ PIN ______ 30 Quick Reference Lock Keypad Commands The following is a list of the keypad commands that are available for the PowerLever Mo...

Reviews: