7

•  One simultaneous flash of the green and red LEDs accompanied by a beep

indicates that the lock is powered.

•  When power drops below a sufficient level for operation, the lock will continu-

ally beep and flash the red LED. At this point, the operator has 5 seconds in
which to regenerate power to a sufficient level before the lock will systemati-
cally shutdown. To regenerate power, depress the outside lever through a 67-
degree open and 67-degree restore rotation.  

•  After each accepted step of an operation, two flashes of the green LED dis-

play and two beeps sound, prompting you to enter additional information for
the next step of the operation. 

The User must wait for these prompts

before proceeding.

•  After you have completed all the steps of an operation, two simultaneous

flashes of the green and red LED display and two beeps sound if the opera-
tion is successful. Two red flashes display and two beeps sound if the opera-
tion is unsuccessful and you will need to re-key the operation which caused
the error.

Programmable Features

The PowerLever Door Lock has the following programmable features.

Lockout

Managerial personnel can control the entry of Access Users and Service Users
by enabling and disabling available entry. Lock entry rights can be programmed
for specific users, groups of users, or all Access Users.

Note: The Master User and the Manager User are not affected by the lockout.

Re-Lock Time

The re-lock time (i.e. the time that the lock remains open before re-locking) can
be programmed by managerial personnel from 2 to 20 seconds, with a 

factory

set default of 4 seconds. The lock automatically re-locks after the re-lock time
has expired. The re-lock is indicated by an audible “click”.

Passage Function

Programming the Passage Function will change the state of the Model 15xx lock
from locked to unlocked. When programmed to the unlocked, or Passage func-
tion, no combination or key override is required for entry. Only managerial per-
sonnel are authorized to program Passage Function. The 

factory default of a

new lock is 

Passage Function = Off (Locked).

6

Communicating with the Lock 

In order to properly operate the lock, you must know what the lock is expecting
you to do and you must also understand what it means when the lock responds
to your actions.

Operating Conventions

The following conventions apply to the operation of the lock:

•  Once the lock is powered, you have a maximum of 20 seconds to enter a valid

combination for an operation.

•  To clear any uncompleted keypad entry, press the 

Clear key. This will clear

any input that was entered since the last accepted input (as indicated by 2
flashes of the green LED along with 2 beeps).

•  To initiate a lock operation other than opening the lock, you must:

1) Power the lock and enter a valid combination
2) Before re-lock, press the 

Enter key followed by the number associated with

the lock operation. For example when adding an Access User, you would
press 

Enter and then 2.

•  When performing multiple passes within an operation for multiple access

users, the Enter key is used as a terminator for the operation.

Lock Responses

The tables below summarize how the red and green LEDs are flashed individu-
ally, simultaneously, or in combination to indicate various conditions. Each LED
flash is accompanied by a beep for audio reinforcement.

Flashes

Green LED

Red LED

Continuous

Low Power

1

Keystroke Entry

2

Input Accepted

General Error

3

Lock Ready to Open

Bad Attempt to Open

4

User ID Added/Deleted Manually

Flashes

Green / Red Sequence

Simultaneous Green-Red

Continuous

1

CLR Key Depression

Lock Powered

2

Device Error **

Procedure End; Re-lock or 
Penalty Time Expired

** 

Contact Technical Support for assistance at 1-800-950-4744.

Summary of Contents for PowerLever 15 Series

Page 1: ...s Control 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 Fax 800 346 9640 336 725 3269 www kaba ilco com Document Number 474 052 1105 Operating Instructions S e r i e s M...

Page 2: ...major assemblies Outside cover assembly includes a keypad for entry of control data a pair of LEDs red and green for visual feedback a beeper for audio feed back and the outside lever with a return o...

Page 3: ...de audio and visual cues to the user when lock power drops below a sufficient level for operation The lock will continually beep and flash the red LED prompting the user to depress the outside lever t...

Page 4: ...x lock The combination can consist of as little as a one digit User ID or the length can be up to six digits in length and consist of a User ID followed by a Personal Identifier Number PIN Regardless...

Page 5: ...Function will change the state of the Model 15xx lock from locked to unlocked When programmed to the unlocked or Passage func tion no combination or key override is required for entry Only managerial...

Page 6: ...limit is the maximum number of consecutive failed entry attempts that can occur before the lock temporarily shuts down to prevent combination tampering The wrong try limit is programmable from 3 9 wi...

Page 7: ...beep flashes of the red and green LEDs Note If a lock has been Activated and then Shelved the lock returns to a state where it can be opened with the default Master User combination of all 0 s The len...

Page 8: ...on User ID only otherwise Combination User ID PIN 12 Change User ID and PIN Lengths The length of the User ID the length of the PIN the length of the combina tion A User ID is mandatory and can vary b...

Page 9: ...verification If the combination was verified suc again cessfully the lock responds with two simultaneous beeps flashes of the green and red LEDs The lock responds with two beeps flashes of the red LE...

Page 10: ...Note If at any time during the procedure the lock power drops below a sufficient level for operation the lock will continually beep and flash the red LED prompting the user to depress the outside leve...

Page 11: ...the combination to open the lock The lock combination will beep flash the green LED on each keystroke entered If the Clear key is pressed during data entry the lock responds with one beep flash of the...

Page 12: ...key is pressed dur ing data entry the lock responds with one beep flash of the green LED followed by the red LED and all digits of the combination must be re entered The lock responds with three beep...

Page 13: ...ous beeps flashes of the green and red LEDs and exits the procedure 22 Disable a Specific User ID This operation allows the Master User or Manager User to restrict access to the lock for a specific Ac...

Page 14: ...nd exits this procedure 24 Disable a Group of User IDs This operation allows the Master User or Manager User to restrict access to an entire user ID group See User ID Groups page 5 for more informatio...

Page 15: ...ltaneous beeps flashes of the green and red LEDs The Manager User is now deactivated 26 Switch Passage Function On Off This operation allows Passage Function to be toggled On and Off Step Detailed Ins...

Page 16: ...l 0 s 28 Change Master User Combination Note The new User ID that is selected must be an available ID one that has not already been selected for another user Step Detailed Instructions 1 Power lock Po...

Page 17: ...___ User ID ___ PIN ______ User ID ___ PIN ______ User ID ___ PIN ______ 30 Quick Reference Lock Keypad Commands The following is a list of the keypad commands that are available for the PowerLever Mo...

Reviews: