background image

15

Set the Re-Lock and Wrong Try Limit and Penalty Times

Step

Detailed Instructions

1.

Power lock.

Power the lock by depressing the outside lever. 

2.

Enter Master User

Enter the Master User or Manager User combina-  

or Manager User 

tion. The lock will beep/flash the green LED on  

combination

each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/
flash of the green LED followed by the red LED, and
all digits of the combination must be re-entered. The
lock responds with three beeps/flashes of the green
LED to indicate available entry. If the combination is
not valid, the lock responds with three beeps/flashes
of the red LED.

3.

Press      then 10.

Before re-lock time expires, press       (Enter key) 
followed by the 1 key and then the 0 key. The lock
responds with two beeps/flashes of the green LED.

4.

Enter two-digit 

Enter a new two-digit re-lock time in the range of  

re-lock time.

02-20 seconds. The lock responds with two 
beeps/flashes of the green LED.

5.

Enter one-digit 

Enter a new one-digit wrong try penalty limit in 

wrong try penalty.

the range of 3-9 tries. The lock responds with two 
beeps/flashes of the green LED.

6.

Enter two-digit 

Enter a new two-digit wrong try penalty time in  

wrong try penalty

the range of 00-20 seconds. The lock responds 

time.

with two simultaneous beeps/flashes of the green 
and red LEDs.

The re-lock time and wrong try limit and penalty 
time are now in effect.

14

Step

Detailed Instructions

5.  Enter Master User

Enter the new Master User combination again for

combination

verification. If the combination was verified suc-

again.

cessfully, the lock responds with two simultaneous
beeps/flashes of the green and red LEDs. The lock
responds with two beeps/flashes of the red LED to
indicate an error.

The lock is now activated and the new Master 
User combination is in effect.

Activate the Manager User

Step

Detailed Instructions

1.

Power lock.

Power the lock by depressing the outside lever. 

2.

Enter Master User

Enter the Master User combination. The lock will 

combination.

beep/flash the green LED on each keystroke
entered. If the 

Clear key is pressed during data

entry, the lock responds with one beep/flash of the
green LED followed by the red LED, and all digits of
the combination must be re-entered. The lock re-
sponds with three beeps/flashes of the green LED
to indicate available entry. If the combination is not
valid, the lock responds with three beeps/flashes of
the red LED. 

3.

Press      then 90.

Before re-lock time expires, press        (Enter key) 
followed by the 

key and then the key. The lock

responds with two beeps/flashes of the green LED.

4.

Enter Manager

Enter the combination for the Manager User. The lock

User combination.

responds with two beeps/flashes of the green LED.

Note: When PIN length = 0, Combination = User ID only; otherwise,
Combination = User ID + PIN. 

5.

Enter Manager 

Enter the Manager User combination again for   

User combination

verification. The lock responds with two simulta- 

again.

neous beeps/flashes of the green and red LEDs if 
the combination was verified successfully. The lock
responds with two beeps/flashes of the red LED to
indicate an error.

The Manager User is now activated with the entered
combination. If PIN length is not 0, the PIN should
be changed immediately for security purposes.

Summary of Contents for PowerLever 15 Series

Page 1: ...s Control 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 Fax 800 346 9640 336 725 3269 www kaba ilco com Document Number 474 052 1105 Operating Instructions S e r i e s M...

Page 2: ...major assemblies Outside cover assembly includes a keypad for entry of control data a pair of LEDs red and green for visual feedback a beeper for audio feed back and the outside lever with a return o...

Page 3: ...de audio and visual cues to the user when lock power drops below a sufficient level for operation The lock will continually beep and flash the red LED prompting the user to depress the outside lever t...

Page 4: ...x lock The combination can consist of as little as a one digit User ID or the length can be up to six digits in length and consist of a User ID followed by a Personal Identifier Number PIN Regardless...

Page 5: ...Function will change the state of the Model 15xx lock from locked to unlocked When programmed to the unlocked or Passage func tion no combination or key override is required for entry Only managerial...

Page 6: ...limit is the maximum number of consecutive failed entry attempts that can occur before the lock temporarily shuts down to prevent combination tampering The wrong try limit is programmable from 3 9 wi...

Page 7: ...beep flashes of the red and green LEDs Note If a lock has been Activated and then Shelved the lock returns to a state where it can be opened with the default Master User combination of all 0 s The len...

Page 8: ...on User ID only otherwise Combination User ID PIN 12 Change User ID and PIN Lengths The length of the User ID the length of the PIN the length of the combina tion A User ID is mandatory and can vary b...

Page 9: ...verification If the combination was verified suc again cessfully the lock responds with two simultaneous beeps flashes of the green and red LEDs The lock responds with two beeps flashes of the red LE...

Page 10: ...Note If at any time during the procedure the lock power drops below a sufficient level for operation the lock will continually beep and flash the red LED prompting the user to depress the outside leve...

Page 11: ...the combination to open the lock The lock combination will beep flash the green LED on each keystroke entered If the Clear key is pressed during data entry the lock responds with one beep flash of the...

Page 12: ...key is pressed dur ing data entry the lock responds with one beep flash of the green LED followed by the red LED and all digits of the combination must be re entered The lock responds with three beep...

Page 13: ...ous beeps flashes of the green and red LEDs and exits the procedure 22 Disable a Specific User ID This operation allows the Master User or Manager User to restrict access to the lock for a specific Ac...

Page 14: ...nd exits this procedure 24 Disable a Group of User IDs This operation allows the Master User or Manager User to restrict access to an entire user ID group See User ID Groups page 5 for more informatio...

Page 15: ...ltaneous beeps flashes of the green and red LEDs The Manager User is now deactivated 26 Switch Passage Function On Off This operation allows Passage Function to be toggled On and Off Step Detailed Ins...

Page 16: ...l 0 s 28 Change Master User Combination Note The new User ID that is selected must be an available ID one that has not already been selected for another user Step Detailed Instructions 1 Power lock Po...

Page 17: ...___ User ID ___ PIN ______ User ID ___ PIN ______ User ID ___ PIN ______ 30 Quick Reference Lock Keypad Commands The following is a list of the keypad commands that are available for the PowerLever Mo...