10
Passage Function
Programming the Passage Function will change the state from locked to unlocked of the PowerLever Door Lock.
When programmed to the un locked, or Passage function, no com bi na tion or key override is re quired for entry. Only
man a ge ri al personnel are au tho rized to program the Passage Function. The factory default of a new lock is Passage
Function = Off (Locked).
Wrong Try Limit and Penalty Time
The wrong try limit is the maximum number of consecutive failed entry attempts that can occur before the lock tem-
porarily shuts down (to prevent combination tampering). The wrong try limit is programmable from 3-9 with a
default of 3.
The penalty time is the time period for which the lock shuts down when the wrong try limit is reached. The shut down
time is pro gram ma ble from 0 to 90 seconds with a factory set default of 20 sec onds. Only man a ge ri al per son nel
are au tho rized to program these pa ram e ters.
During the shutdown period, the lock will not respond to any user actions. If you attempt to power the lock during the
shutdown period, the lock will display two simultaneous flashes of the red LED to indicate an error condition. When
the shut down period has elapsed the lock will respond to user actions. Each additional wrong try will result in the
lock shutting down for the programmed penalty time. This cycle will continue until a correct combination is entered
for a Keypad User or a valid Smart Key is presented for a Key Access User.
Audit Features
Audit features require the PowerLever software to report on the audit and user information retrieved from the lock. If
you have pur chased the PowerLever Door Lock PC software for reporting capabilities, data stored in the lock can be
read from the lock and taken to the PC for re port ing. See the PowerLever Door Lock Software Reference Manual for
more detail.
Retrieve Audit Records
The lock’s audit feature will track the fol low ing types of lock trans ac tions in se quen tial order of occurrence:
• lock user table configured (i.e., number of Smart Key
users and Keypad User PIN field length)
• lock opened
• lock activated
• lock shelved
• PIN / combination changed
• add User ID
• delete User ID
• user enabled
• user disabled
• re-lock / wrong try penalty time set
• failed attempts penalty
• audit report retrieved
• set date/time
• Daylight Savings Time ON
• Standard Time ON
• holiday / Daylight Savings Time changeover data
loaded to lock
• Service User activated
• Audit User activated
• Access User report retrieved
• Passage Mode ON
• Passage Mode OFF
• Manager User activated
• Manager User deactivated
• Master combination reset via hardware button
• lock disabled to Access Users and Service Users
• lock enabled to Access Users and Service Users
• Palm handheld connect
• Palm handheld disconnect