Step
Detailed Instructions
3.
Press then 50.
Before re-lock time expires, press (Enter key) followed by the 5 key and
then the 0 key. The lock re sponds with two beeps/flashes of the green LED.
4.
Enter new Master User
Enter the new Master User combination. The lock responds with two beeps/
combination.
flashes of the green LED.
Note: The User ID selected must be in the range from 0 to the number of keypad users minus one.
Note:When PIN length = 0, Combination = User ID only; otherwise, Combination = User ID + PIN.
5.
Enter Master User
Enter the Master User’s new combination again for ver i fi ca tion. The lock
combination again.
responds with two si mul ta neous beeps/flashes of the green and red LEDs if
the com bi na tion was verified suc cess ful ly. The lock responds with two
beeps/flashes of the red LED to indicate an error.
The lock is now activated and the new Master User combination is in effect.
Activate a Manager User
Note: As many Manager Users can be activated as there are available keypad user table spaces in the lock.
Step
Detailed Instructions
1.
Power lock.
Power the lock by depressing the outside lever.
2.
Enter Master User
Enter the Master User combination. The lock will beep/flash the green LED
combination.
on each key stroke entered. If the Clear key is pressed during data entry, the
lock re sponds with one al ter nate beep/flash of the green and red LED, and
all digits of the combination must be re-entered.
The lock responds with three beeps/flashes of the green LED to indicate
available entry. If the combination is not valid, the lock responds with three
beeps/flashes of the red LED.
3.
Press then 90.
Before re-lock time expires, press (Enter key) followed by the 9 key and
then the 0 key. The lock re sponds with two beeps/flashes of the green LED.
4.
Enter Manager User
Enter the combination for the Manager User. The lock re sponds with two
combination.
beeps/flashes of the green LED.
Note: The User ID selected must be in the range from 0 to the number of keypad users minus one.
5.
Enter Manager User
Enter the Manager User combination again for verification. The lock
combination again.
responds with two simultaneous beeps/flashes of the green and red LEDs if
the com bi na tion was verified suc cess ful ly. The lock re sponds with two
beeps/flashes of the red LED to indicate an error.
If PIN length > 0, the Manager User must change his PIN in order to activate
his combination.