This guide provides a quick summary of information necessary for the operation of
the PowerLever PROX 9000 Series system.  Prior to using the Quick Reference
Guide, you should have completed all activities outlined in the 

Getting Started

Guide

. The Quick Reference Guide is intended to cover the basic operational

functions of the lock at the keypad. For more detailed information on the entire
system, refer to the 

PowerLever PROX 9000 Series Reference Manual

.

System Components

Locks

PROX Cards

PC & PowerLever PX Software

M-Unit & LockCom PX Software

Lock Modes

A lock can operate in one of 3 different modes:

Default Factory Mode

The lock is shipped from the factory in Default Factory Mode and is opera-
tional after being installed. The lock can only be opened with the Default
Factory Master User PIN of “12345678”.

Construction (Temporary Activated) Mode

The lock can be switched from Factory Mode to Construction Mode manu-
ally and can operate without interfacing with the PowerLever PX Software
via the M-Unit. When in Construction Mode, PROX Cards can be enrolled
for access to the lock. The lock can only be opened via the presentation of
the PROX Card, although the Master User PIN is also authorized to open
the lock in this mode. For detailed information on how to operate the lock in
Construction Mode, refer to the 

Construction Mode Operations

 sheet that

was shipped with the lock.

Activated Mode  (Using Software)

When lock and lock user data is defined at the PC using the PowerLever
PX Software and then uploaded to the lock via the M-Unit, the lock is
considered to be in Activated Mode. When in Activated Mode, the default
method of lock access is PIN and PROX Card, but access can also be set to
require only a PIN or only a PROX Card.

Summary of Contents for PowerLever PROX 9000

Page 1: ...Quick Reference Guide POWERLEVER PROX 9 0 0 0 Series...

Page 2: ...t represent a commitment on the part of Kaba Mas Kaba Mas shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from...

Page 3: ...Set Lock Time 6 Set Lock s Relock Time 7 Set Tamper Shutdown Time 7 Set Wrong Try Limit 7 Toggle Daylight Savings Time Standard Time 7 Add PROX Card for Master User 7 Remove PROX Card for Master User...

Page 4: ......

Page 5: ...th the Default Factory Master User PIN of 12345678 Construction Temporary Activated Mode The lock can be switched from Factory Mode to Construction Mode manu ally and can operate without interfacing w...

Page 6: ...ck and user are set up for PIN and PROX access the user has a maximum of 5 seconds after entering a valid PIN to present the PROX Card The PROX Reader is located on the front of the lock just below th...

Page 7: ...panied by a beep indicates that the lock is powered for opening When power drops below a sufficient level for operation the lock will continually beep and flash the red LED At this point the operator...

Page 8: ...ard for Master User p 7 and then 012 Remove PROX Card for Master User p 7 and then 300 Enable Access User p 8 and then 301 Enable Manager User p 8 and then 302 Enable Service User p 8 and then 303 Ena...

Page 9: ...er User PIN of 12345678 3 Depress outside lever to open lock System Maintenance at Lock Change Default Factory Master User PIN 1 Power lock 2 Enter Default Factory Master User PIN of 12345678 3 Press...

Page 10: ...with PIN Only 1 Power lock 2 Enter PIN 3 Depress outside lever to open lock System Maintenance at Lock Set Lock Date 1 Power lock 2 If PIN is required enter Master User PIN Manager User PIN or M Unit...

Page 11: ...quired enter Master User PIN or a Manager User PIN 3 If PROX Card is required present PROX Card 4 Press followed by 007 5 Enter one digit wrong try penalty limit 4 9 tries Toggle Daylight Savings Time...

Page 12: ...PIN is required enter Master User PIN or a Manager User PIN 3 If PROX Card is required present PROX Card 4 Press followed by 302 5 Enter PIN of Service User to be enabled Enable M Unit User 1 Power l...

Page 13: ...f PIN is required enter Master User PIN or a Manager User PIN 3 If PROX Card is required present PROX Card 4 Press followed by 402 5 Enter PIN of Service User to be disabled Disable M Unit User 1 Powe...

Page 14: ...Card 4 Press followed by 801 The lock settings are returned to the default Factory Mode settings All Access Users are deleted but the lock retains the current Master User PIN and PROX if applicable R...

Page 15: ...settings All users are deleted and the Master User PIN is reset to the Default Factory Master User PIN of 12345678 The lock is fully reset to Factory Mode Establish Communications Between Lock M Unit...

Page 16: ...12...

Page 17: ...NOTES...

Page 18: ......

Page 19: ......

Page 20: ...86 093 Rev A 04 04 Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 FAX 800 346 9640 336 725 3269 Technical Support 800 950 4744 www kaba ilco com www p...

Reviews: