Testing Lock Functionality

Pass a Construction key over the QuantumII MT RFID reader. The green light will flash for five seconds. Be sure that the 
green light flashes for five seconds while the exterior lever remains operable. If the green lights do not flash, refer to  
the table below.

Lock Communication 

 Electronic Function Description

Red and green LEDs flash  

 Time and date not set, use the Quantum MT RFID LPI probe to reset

 

nine times simultaneously 

 

Yellow LED flashes 12 times 

 

Dead bolt is thrown or switch cam is not properly aligned

Yellow LED flashes two times 

 Keycard not allowed OR keycard cancelled by new keycard

Red and green LEDs flash 

 Low battery (contact the SAFLOK service department)

alternately nine times

Yellow and red LEDs flash  

 

Bad keycard read or corrupted data (may require new 

two times simultaneously 

 keycard)

Summary of Contents for Saflok QuantumII MT RFID

Page 1: ... property is confidential and intended for the sole use of the addressee s so named Any misuse of this confidential information contained herein may result in legal action by Computerized Security Systems dba SAFLOK and its parent company Proximity Reader Assembly A21710 COLOR Mortise see Mortise Options table Scalp Plate 51190 COLOR Outside Lever Trim A20970 HAND COLOR Screw Pack A29070 COLOR Str...

Page 2: ...nd confirm that the existing door edge prep is appropriate for the SAFLOK mortise lock Drill fixture If you are using a SAFLOK drill fixture position and clamp the fixture on the door The fixture has two positioning posts that rest inside the mortise establishing the proper backset for the trim When the fixture is clamped its surfaces should be parallel with the door surfaces and door edges Not al...

Page 3: ...pinched or pulled as the mortise is inserted into the pocket 4 Attach the mortise front plate to the door using the two mortise screws 12 x 1 1 4 screws for wood doors 12 24 x 3 8 screws for metal doors Be sure that the screws are fully tightened Important DO NOT leave the screws loose The screws must be fully tightened before the trim is installed If you must leave the mortise loose to install th...

Page 4: ...r Do not pull on the ribbon cable DO NOT CREASE THE RIBBON CONNECTOR 3 Position the inside trim on the inside of the door 4 Secure inside trim to the proximity card reader assembly to the inside trim using three M5 x 31 mm screws Important Do not fully tighten the screws at this point 5 Align the outside lever trim with the diagonal holes located on either side of the mortise hub and secure it usi...

Page 5: ... the switch cam should be at the right 3 00 position when the mortise dead bolt is retracted see Fig 6 The retaining ring should rest on the switch cam when fully inserted the proper positioning of the cam will allow the door to be opened when the dead bolt is retracted and block entry when the dead bolt is thrown for privacy except when emergency keycards are used Position dead bolt spindle assem...

Page 6: ...nd Interrogator LPI probe with the LPI R device cable Test the functioning of the lock as discussed in the following section and in the programming manual before closing the door When the construction key is used the green and red LEDs will blink together indicating that the lock s time and date are not set 15 For humid outdoor environments apply dielectric grease inside the USB connector after pr...

Page 7: ...er to the table below Lock Communication Electronic Function Description Red and green LEDs flash Time and date not set use the Quantum MT RFID LPI probe to reset nine times simultaneously Yellow LED flashes 12 times Dead bolt is thrown or switch cam is not properly aligned Yellow LED flashes two times Keycard not allowed OR keycard cancelled by new keycard Red and green LEDs flash Low battery con...

Page 8: ...2 times when the dead bolt is extended and a guest hotel keycard is used All keycards function to the specifications of the properties key design Door function Door closes and latches with little or no interference Dead bolt extends fully through the strike plate without interference door closed Spacing between door edge and inside door jamb does not exceed 3 16 door closed Note If bumpers or othe...

Reviews: