background image

7

I-1

Make certain the lever catch is up as shown

(c). The lever catch should be flush around the

outer diameter of the outside driver. Make

certain the lever sleeve (f) is rotated to

properly mate with the outside lever/knob.

I-2

Insert one of the supplied keys (a) into the

outside lever/knob (b) and rotate key

counterclockwise 45 degrees.

I-3

Insert the outside lever/knob (b) until it is flush to the

outside unit assembly (levers fit closer than knobs).

Secure the outside lever/knob by rotating the key

clockwise 45 degrees to the horizontal position. Remove key.

Note:

To remove the outside lever/knob from

the outside unit assembly, follow steps below.

I-4

Insert one of the supplied keys (a)

into the outside lever/knob and

rotate it counterclockwise 45

degrees. Insert the release tool (d)

into the small hole (e) under the

lever/knob as shown. Gently push

the lever catch up until it clicks.

Remove tool, then remove the

outside lever/knob.

J.

INSTALLING/REMOVING
OUTSIDE LEVER/KNOB

(Interchangeable/ Removable Core Models)

Note:

Installing levers/knobs to the unit assemblies before

mounting the unit assemblies, may ease initial installation.

J-1

Make certain the lever catch is up as shown (c). The

lever catch should be flush around the entire diameter

of the outside driver. Make certain the lever sleeve (f) is

rotated to properly mate with the outside lever/knob.

J-2

Insert the outside lever/knob (a) until it

is flush to the outside unit assembly (b)

(levers fit closer than knobs). Insert the

release tool (d) (or screw- driver) into

the outside lever/knob as shown, and

slide the lever catch down until it clicks.

Note

: For all interchangeable/removable

cores except ASSA/Medeco/Yale, proceed

to section J-3. For ASSA/Medeco/Yale

cores, skip to section J-5.

6

H-2

Determine the proper tailpiece (d) needed for

your KIL/KIK cylinder from the chart above.

You must use a KABA tailpiece. The K-2 tailpiece

is preassembled with the 1599 cylinder.

H-3

Assemble the required tailpiece (d) supplied with

your KIL/KIK cylinder. All tailpieces must be

installed vertically as shown for proper

installation.

H-4

Insert the KIL/KIK cylinder (a) into the outside

lever/knob (b) and secure it with the cylinder

retainer (c) and lever insert (e) (no insert on the

knob). The KIL/KIK cylinder should be snug and

unable to move freely.

I.

INSTALLING/REMOVING
OUTSIDE LEVER/KNOB

(Key-in-Lever/Knob Models only) (For

interchangeable and removable cores,

proceed to section J)

Note:

Installing lever/knob to the unit assemblies before

mounting the unit assemblies, may ease initial installation.

b

a

e

d

c

KIL Lever Sleeve

LH

RH

c

Correct

Position

Incorrect

Position

f

c

Correct

Position

Incorrect

Position

b

a

d

c

b

a

d

e

c

vertical

a

b

45º

b

a

IC Lever Sleeve

LH

RH

f

e

a

45º

d

d

e

a

b

b

d

d

a

a

Assa 65611, Australian: Kaba experT 107K5 &

Boyd KC286, Corbin-Russwin 2000-03, Kaba

1599, Schlage 23-001, Schlage Primus 20-760,

Kaba Peaks 1099

Medeco 20W200H1

Arrow C100, Sargent 10 LINE

Marks

Abloy 5277, Abloy 5477, Assa 65691,

Kaba 15396, Kaba Gemini 4730

KIL/KIK CYLINDER

TAILPIECE

K1

K3

K2

K4

K5

Summary of Contents for Simplex 5000 Series

Page 1: ...Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 Fax 800 346 9640 336 725 3269 www kabaaccess com PKG2842 0407 5000 CYLINDRICAL INSTALLATION INSTRUCTIONS ...

Page 2: ...se damage Kaba Access Control s warranty does not cover damages caused by installation Caution Wear safety glasses when preparing door TABLE OF CONTENTS Exploded Install Parts 1 Tools Required 1 A Door Preparation 2 B Lock Handing 3 C Door Thickness 3 D Installing The Passage Set 4 E Installing Outside Unit Assembly 5 F Installing Inside Unit Assembly 5 G Installing The Inside Lever Knob 6 H Chang...

Page 3: ...he cylindrical drive unit b Rotate cylindrical drive unit 180 degrees Reposition spacer c as found before disassembly Remount drive unit with the two connecting screws C DOOR THICKNESS The Simplex 5000 lock is preassembled to accommodate standard door thickness 1 5 8 41 mm to 2 51 mm C 1 Reference Figure A For thinner door applications of 1 3 8 35 mm to 1 1 2 38 mm Remove and discard the two conne...

Page 4: ... or key cylinder should rotate 90 degrees clockwise so that the arrow knob is pointing up or the dot key cylinder is at the top Note Leave the actuator set in this position for installation if key cylinder is used remove the key at this point Note The tailpiece of the passage actuator is scored on several places to allow you to easily break off the section that extends beyond the required length t...

Page 5: ... outside unit assembly b levers fit closer than knobs Insert the release tool d or screw driver into the outside lever knob as shown and slide the lever catch down until it clicks Note For all interchangeable removable cores except ASSA Medeco Yale proceed to section J 3 For ASSA Medeco Yale cores skip to section J 5 6 H 2 Determine the proper tailpiece d needed for your KIL KIK cylinder from the ...

Page 6: ...rstop is required we recommend the use of a floor secured stop The environment and conditions of use determine the life of finishes on Kaba Access Control products Finishes on Kaba Access Control products are subject to change due to wear and environmental corrosion Kaba Access Control cannot be held responsible for the deterioration of finishes Authorization to Return Goods Returned merchandise w...

Page 7: ...n Door Exercise Room This lock is New Installation Replacing a conventional keyed lock Replacing a Kaba Mechanical Pushbutton Lock Replacing a Kaba Electronic Access Control Replacing a Keyless Lock other than Kaba How did you learn about Kaba Access Control Pushbutton Locks Advertisement Previous Use Internet Web Another Use Locksmith Maintenance Training Class Other please specify What was your ...

Page 8: ...he outside lever knob Rotate key counterclockwise to stop position and hold Ensure that the latch is fully retracted and flush with the latch faceplate Rotate key clockwise to horizontal position and remove key The latch should be fully extended 10 J 3 Insert the supplied tailpiece e with the flat installed vertically into the outside lever knob b as shown Make certain you rotate the tailpiece so ...

Page 9: ...he door frame making certain that the strike opening is aligned a with the latch bolt L 2 Mortise doorframe for strike 3 32 3 mm deep minimum to dimensions shown Secure strike b to the door frame using two 1 25 mm combination screws c supplied M CHANGING COMBINATIONS Note The factory set combination of your new 5000 series Press 2 and 4 at the same time then release Press 3 then release Press the ...

Page 10: ...press the wrong key stem by mistake rotate the reset cam back toward you toward the key stems and release This resets the code gears and you must repeat the above procedure O 3 14 N INSTALLING RUBBER BUMPERS N 1 Close the door and apply pressure making sure the deadlatch a rests on the strike plate b as shown Standing on the frame door stop side of the door check for gaps between the door and the ...

Page 11: ...e and release Rotate the reset cam back toward you with your finger toward the key stems as far as it will go and release Enter your new combination code by depressing the key stem corresponding to the first number 1 through 5 of your code For example if the new code is 3 2 5 then you would depress 3 first then 2 and finally 5 Record this new combination code for future reference Push the shoulder...

Page 12: ...19 18 Notes Notes ...

Reviews: