6.15 Fault list
Fault
Possible cause
Remedy
Operational readiness
cannot be established
Main switch is in “off” position
Set main switch to “on” position
Mains plug not inserted
Insert mains plug
Machine cannot be
switched on
No connection for compressed-
air supply system
Make connection for compressed-
air supply system
Compressed-air supply
specifications do not match
rating plate specifications
Set the compressed-air supply
pressure to no more than 6 bar
Emergency stop button engaged
Release the
emergency stop button
Protective hood open
Close the protective hood
Cable set taping too loose Winding aid value set too high
Reduce the value
Cable set taping too tight
Winding aid value set too low
Increase the value