~ 5 ~ 

 

2 Safety

 

 

This section includes a summary of points from the manual concerning safety for the procedures you 
will follow. 

 

 

2.1 General safety 

 

Warning:   

Kabola  Heating  Systems  designs  and  builds  its  products  according  to  the 
current  best  available  techniques.  However,  it  is  possible  that  dangers  may 
occur  that  can  result  in  injuries  or  damage  to  the  boilers  if  the  safety 
instructions are not followed. 

 

The user must: 

 

  Hav

e read and understood the ‘Safety’ section; 

  Not carry out any activities that may endanger health; 

  Not carry out any activities that may cause damage to the boiler; 

  Ensure that the boiler is only used when it is in a technically good condition and has been installed 

in the correct way; 

  Ensure that the safety measures are complied with during use of the boiler. 

 

Note: 

No changes may be made to the boilers without the explicit written 
permission of Kabola Heating Systems! 

 

 

2.2 

Safety instructions

 

 

The safety instructions specified below must be followed when using the Kabola boiler. 

 

MEASURES FOR SAFE INSTALLATION

 

 

  Do not place any flammable and/or gaseous substances that may cause danger of explosion or fire 

in the space where the boiler is or is to be installed. 

  Install the boiler in a moisture-free space on a strong, horizontal surface. 

  Fasten the boiler with the assembly bolts (M5) supplied for that purpose. 

  Ensure sufficient ventilation in the space where the boiler is installed (see § 4.1.1). 

  Provide an earthed wall socket (230 V AC) for the connection of the boiler. 

  Before you start connecting make sure there is no voltage on the system. 

  For the electrical connections and thermostat connections only use multi-core cables with flexible 

core (minimum 0.75 mm2). 

 

MEASURES FOR SAFE USE

 

 

  Never change the burner settings on your own initiative. 

  When cleaning the boiler do not use any aggressive cleaning products that may corrode the boiler. 

  Have the boiler settings checked each year by a specialist installer. 

  Before you start working on the boiler make sure there is no voltage on the system. 

  Collect any oil that may be released. 

  It is recommended to only have maintenance and repair activities carried out by specialist and 

Kabola-certified persons. 

 
 
 
 
 

 

 

Summary of Contents for HR Series

Page 1: ...1 Userguide HR HRE series Eng HRE CH HR CH HR Calorifier HR Combi...

Page 2: ...s shown below Tip A tip gives the user suggestions and advice to be able to carry out certain tasks more easily Note The user is given additional information here Any potential problems are also cover...

Page 3: ...y 8 4 1 4 Flue gas outlet 9 4 1 5 Electrical connection 12 4 1 6 Filling the central heating system 13 4 1 7 Mounting the oil burner 13 4 1 8 Mounting the oil filter and oil burner 14 4 2 Starting you...

Page 4: ...e space in which they are installed Heating only takes place using radiators a hot air system underfloor heating and or any custom made airco systems in which the Kabola boiler is integrated When usin...

Page 5: ...Kabola boiler MEASURES FOR SAFE INSTALLATION Do not place any flammable and or gaseous substances that may cause danger of explosion or fire in the space where the boiler is or is to be installed Inst...

Page 6: ...owing points must be observed Make sure that the casing cannot be damaged Use a blanket for example Transport the boiler upright with the base below 3 2 Storage When the boiler is to be stored for lon...

Page 7: ...with bolts or tack welding Make sure there is a distance between the outlet and the wall of at least 10 20 mm because of the heat transfer from the flue gas outlet Ensure sufficient space around the b...

Page 8: ...Assemble the boiler vessel supply at point 3 4 Assemble the separately supplied filler tap and drain combination at point 4 see fig 2 5 The letters B and A are market on the 3way valve Note Fig 2 A b...

Page 9: ...the flue gas outlet horizontally from the boiler through the wall The following points must then be respected The maximum permitted length without bends is 3 meters Make sure that the outlet is amply...

Page 10: ...ws 90 The maximum allowed length is 10 meters At more than 10 meters in length always contact Kabola for advice Every elbow of 90 is equivalent to 1 meter straight pipe Use outside double walled chimn...

Page 11: ...Boiler Remove the 7 pin connector at the rear left side of the front panel see Figure 8 Remove the lid from the 7 pin connector Remove the bridge of T1 and T2 connect here the thermostat wires see sti...

Page 12: ...HR Calorifier and combi Connect the wires of the hot water on off function on the points S3 and B4 as indicated on the sticker in the plug frost guard see Figure 11 Only at the HR boiler with calorifi...

Page 13: ...her Set the on off switch button lights Put the heating pump in automatic venting position Control knob to 12 hours see Figure 9 Turn a quarter of a turn the red button after about 5 minutes to positi...

Page 14: ...4 and 15 Connect the oil line directly from the fuel tank to the filter no branch from other users oil see Figure 15 connector C Venting of the oil filter to pass through swivel rotating D counter clo...

Page 15: ...completely open Open airscrew D by turning left see Figure 15 Keep repeating this until there are clear oil comes out of the hose If the red fault light of the oil burner lit reset it by pushing it I...

Page 16: ...r you will find a list of possible problems and solutions in Appendix C Operating the room thermostat Please refer to the manual thermostat HRE Boiler Put the boiler temperature between 75 and 80 C wi...

Page 17: ...l Set the boiler temperature to 80 degrees Celsius press boiler thermostat button in and turn Numbers Explanation Photo 0 Rest position boiler is on stand by Circulation pump stopped 1 Room thermostat...

Page 18: ...ning time 0 seconds Flashing point hot water off Point lit up hot water stand by The figure 19 on the right of the display shows the current boiler water temperature Operating panel HR Calorifier fron...

Page 19: ...sition Boiler kept at temperature Flashing point hot water off Point lit up hot water stand by The figure 19 on the right of the display shows the current boiler water temperature HR combi boiler Oper...

Page 20: ...ler using a pipe cleaner Note Do not use any aggressive cleaning products when cleaning 1 5 Suck the heating boiler empty with a vacuum cleaner 1 6 Replace the boiler gasket 1 7 Replace the boiler doo...

Page 21: ...21...

Page 22: ...Appendix B Electrical diagram 230V HR HRE CH...

Page 23: ...Appendix B Electrical diagram 230 V...

Page 24: ...rrupted Clear chimney opening Boiler dirty Clean boiler Oil supply interrupted See above Nozzle defective Replace nozzle Burner shows error Reset burner once Low voltage Check voltage level Oil supply...