background image

Remote 

Controller 

Manual

CASSETTE AIR CONDITIONER

KCS Series

KCS24 | KCS36 | KCS42 | KCS48

Mode ON/OFF

Fan

+

-

Timer

Sleep

LED

Follow

me

Turbo

Short

Cut

Self

clean

Summary of Contents for KCS Series

Page 1: ...Remote Controller Manual CASSETTE AIR CONDITIONER KCS Series KCS24 KCS36 KCS42 KCS48 Mode ON OFF Fan Timer Sleep LED Follow me Turbo Short Cut Self clean...

Page 2: ......

Page 3: ...Y operation dehumidifying 8 FAN operation 8 HEAT operation 9 Setting the TIMER function 10 Setting both TIMER ON and TIMER OFF at the same time 11 6 Advanced functions 13 SLEEP function 13 TURBO funct...

Page 4: ...es as follows AUTO COOL DRY HEAT FAN TIMER Set timer to turn unit on and off see Basic Functions for instructions SLEEP Saves energy during sleeping hours LED Turns indoor unit s LED display on and of...

Page 5: ...als properly 2 Install the holder with two screws 3 Put the remote controller in the holder Battery notes For optimum product performance Do not mix old and new batteries or batteries of different typ...

Page 6: ...Displays when TIMER ON is set ON TIMER OFF display Displays when TIMER OFF is set OFF Silent feature display Follow me feature display LOCK feature display Sleep mode display Battery display Low batte...

Page 7: ...ED can t be set in Auto mode COOL operation 1 Press the MODE button to select COOL mode 2 Set your desired temperature using the Temp or Temp button 3 Press the FAN button to select the fan speed 4 Pr...

Page 8: ...t be set in DRY mode FAN operation 1 Press the MODE button to select FAN mode 2 Press the FAN button to select the fan speed 3 Press the ON OFF button to start the unit NOTE You can t set temperature...

Page 9: ...the FAN button to select the fan speed 4 Press the ON OFF button to start the unit NOTE As outdoor temperature drops the performance of your unit s HEAT function may be affected In such instances we...

Page 10: ...s you to set a period of time after which the unit will automatically turn off such as when you wake up 1 Press the Timer button the Timer off indicator displays and flashes By default the last time p...

Page 11: ...hours after the current time For example say that the current time is 1 00 PM and you want the unit to turn on automatically at 7 00 PM You want it to operate for 2 hours then automatically turn off...

Page 12: ...rate for 2 hours then turn off see figure below Your remote display 6 hours later 8 hours later Timer starts Unit turns ON 2PM 3PM 4PM 5PM 6PM 7PM 8PM 9PM Current time 1PM Timer is set to turn ON 6 ho...

Page 13: ...temperature in the shortest amount of time possible When you select TURBO feature in COOL HEAT mode the unit will blow cool hot air with strongest wind setting to jump start the cooling heating proces...

Page 14: ...nction Swing button Used to stop or start vertical louvre movement and set the desired left right air flow direction The vertical louvre changes 6 degrees in angle for each press If held down for more...

Page 15: ...e current settings or resume previous settings If this button is pushed when the remote controller is on the system will automatically revert back to the saved settings including operating mode settin...

Page 16: ...kadenair com au...

Reviews: