1. Safety precautions

Read safety precautions before installation

Thank you for purchasing this air conditioner. This manual will provide you with information on how to operate, maintain, and 
troubleshoot your air conditioner. Following the instructions will ensure the proper function and extended lifespan of your unit.

Please pay attention to the following signs:

 WARNING

• Ask an authorised technician to install this air conditioner. Inappropriate installation may cause water leakage, electric

shock, or fire.

• The warranty will be voided if the unit is not installed by professionals.

• If abnormal situation arises (like burning smell), turn off the power supply and call an authorised technician for instructions

to avoid electric shock, fire or injury.

Do not

 let the indoor unit or the remote control get wet. It may cause electric shock or fire.

Do not

 insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating

at high speeds.

Do not

 use a flammable spray such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.

CAUTION

Do not

 touch the air outlet while the swing flap is in motion. Fingers might get caught or the unit may break down.

Do not

 inspect the unit by yourself. Ask an authorised technician to perform the inspection.

• To prevent product deterioration, 

do not

 use the air conditioner for preservation purposes (storage of food, plants, animals,

works of art, etc.).

Do not

 touch the evaporator coils inside the indoor unit. The evaporator coils are sharp and may cause injury.

Do not

 operate the air conditioner with wet hands. It may cause electric shock.

Do not

 place items that might be affected by moisture damage under the indoor unit. Condensation can occur at a relative

humidity of 80%.

Do not

 expose heat-producing appliances to cold air or place them under the indoor unit. This may cause incomplete

combustion or deformation of the unit due to the heat.

• After long periods of usage, check the indoor unit to see if anything is damaged. If the indoor unit is damaged, it may fall

and cause injury.

• If the air conditioner is used together with other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.

Do not

 climb onto or place objects on top of the outdoor unit.

This symbol is a CAUTION, and indicates that ignoring instructions may cause moderate injury to your person,
or damage to your unit or other property.

This symbol is a WARNING, and indicates that ignoring instructions may cause death or serious injury.

Summary of Contents for KDI36

Page 1: ...Owner s Manual DUCTED AIR CONDITIONER KDI Series KDI36 KDI42 KDI48 KDI60...

Page 2: ...ent AS NZS 3000 AS NZS 5149 Local Regulations and Municipal Building Codes including local OH S requirements This appliance must be installed maintained and removed only by an Authorised Person For co...

Page 3: ...for future reference 1 Safety precautions 4 2 Indoor unit parts and major functions 6 Unit parts 6 Operating conditions 6 Features 6 Energy saving tips 7 3 Installation and service 8 4 Care and mainte...

Page 4: ...s in motion Fingers might get caught or the unit may break down Do not inspect the unit by yourself Ask an authorised technician to perform the inspection To prevent product deterioration do not use t...

Page 5: ...ion device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating of above 10mA shall be incorporated in the xed wiring according to the national rule...

Page 6: ...When the air conditioner restarts after a power failure it will default to the factory settings AUTO mode AUTO fan 24 C This may cause inconsistencies on the remote control and unit panel Use your re...

Page 7: ...keep cool or warm air in the room There is no direct radiation from heaters Do not place objects near the air inlet and outlet of the unit This will reduce the ef ciency of the unit Set a timer and us...

Page 8: ...etails Model number _______________________________________________________________________________________ Serial number indoor unit __________________________________________________________________...

Page 9: ...rack or deform Do not wash the unit under running water Doing so causes electrical danger Do not use water hotter than 40 C to clean the front panel This can cause the panel to deform or become discol...

Page 10: ...e lit up the outdoor temperature is too cold and the unit s defrost cycle is activated in order to defrost the unit The unit changes from COOL mode to FAN mode The unit changes its setting to prevent...

Page 11: ...noises The unit will make different sounds based on its current operating mode Dust is emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use w...

Page 12: ...eat exchanger The air filter is dirty Remove the filter and clean it according to instructions The air inlet or outlet of either unit is blocked Call service agent Doors and windows are open Make sure...

Page 13: ...between indoor main board chips 9 Off EH0b 11 Outdoor ambient temperature sensor error 5 Off EC53 12 Outdoor condenser pipe sensor error 5 Off EC52 13 Compressor discharge temperature sensor error 5...

Page 14: ...ehold waste or unsorted municipal waste When disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility Sell the a...