Putting in operation
1. Replace the belt guard.
2. Connect the negative cable to the battery.
3. Switch on the «Controller ON/OFF» switch.
4. Close the doors.
10.4.10 Having the anti-vibration mount checked
Anti-vibration mounts are elastomer metal elements, that are used, for example, for vibration-
dampened bearing of the drive of construction machines. They consist of two U-profiles that are
fastened to each other through an elastomer.
Fig. 48 Example for anti-vibration mount of drive engine
1
Anti-vibration mount
2
Bottom U-profile
3
Elastomer
4
Top U-profile
➤ Have the anti-vibration mount of the drive engine checked by an authorized KAESER service
representative.
Elastomer of anti-vibration mount is destroyed or porous.
➤ Have the anti-vibration mount replaced by an authorized KAESER service representative.
10.4.11 Battery maintenance
➤ Check the charging system if the batteries discharge for no obvious reason.
10.4.11.1 Safety
Danger of acid burns from escaping electrolyte!
➤ Wear appropriate protective clothing including acid-proof rubber gloves.
➤ Always wear eye and face protection.
➤ Do not tip the battery. Electrolyte may run out of vent holes.
➤ Work with caution.
When working on batteries, comply with the following safety signs
A warning label with safety signs is attached to the battery.
10 Maintenance
10.4 Drive engine maintenance
126
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M55 PE SIGMA CONTROL SMART pV
No.: 902366 10 USE