➤ Memorize the layout of the starting instruments on the control panel.
To ensure a gentle shutdown, always switch off the machine using the «OFF» key on the
control panel of the SIGMA CONTROL SMART. This is indicated clearly by the
NORMAL
OFF label to the right of the SIGMA CONTROL SMART control unit.
Use the «EMERGENCY STOP» push button for emergencies only.
8.2.2 SIGMA CONTROL SMART control unit
Fig. 18 Keys and indicators, SIGMA CONTROL SMART control unit
9
«Up» and «Down» keys
10
«Enter» key
11
«LOAD/IDLE» key
12
«OFF» key
13
«START» key
14
Status bar
a
Control voltage ON
b
READY (flashing)
15
Menu bar
c
Settings menu
16
Navigation menu
➤ Memorize the keys and indicators on the control unit.
8.2.3 Controller ON/OFF switch
The control voltage for the SIGMA CONTROL SMART control unit is switched on when the
«Controller ON/OFF» switch is set to
ON. The «Controller ON/OFF» switch is located inside the
machine.
8
Operation
8.2
Starting up and shutting down
No.: 902366 10 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M55 PE SIGMA CONTROL SMART pV
65