➤ Restart the SIGMA CONTROL SMART to acknowledge the warning message.
The message is acknowledged.
The machine can be started.
Further information For more information regarding the event memory, see the separate operating manual for the
SIGMA CONTROL SMART.
8.5 Cleaning the machine after operation
Proper technical condition of the machine also includes cleanliness. The interior of the ma‐
chine in particular should not be heavily contaminated with oil.
When cleaning the interior of the machine by using a high-pressure cleaner you must take
appropriate measures to effectively protect the electrical components from any penetrating
water.
➤ The machine must be cleaned by authorized and trained personnel only!
Maintain the following minimum distances to the object to be cleaned:
■ Circular section jet nozzles: approximately 28 inches
■ Fan jet nozzles: approximately 12 inches
■ Dirt blasters: approximately 12 inches
Cleaning by using dry-ice blasting is strictly forbidden! This can result in unforeseen dam‐
age.
Material Eye protection (protective glasses)
Cleaning cloth
High-pressure washer
Precondition The machine has been set down in a cleaning area equipped with an oil separator.
The machine is on level ground and has cooled down.
The machine is completely depressurized,
the pressure gauge reads 0 psig!
Controller ON/OFF switch is switched off,
the minus cable of the battery has been disconnected.
Stirred up dirt particles and hazardous materials!
Injuries to eyes.
➤ Wear safety glasses.
8
Operation
8.5
Cleaning the machine after operation
No.: 902366 10 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M55 PE SIGMA CONTROL SMART pV