3.2.2 Indicator elements and interfaces
Fig. 5 KAESER i.Box − indicator elements and interfaces
1
Antenna connection SMA (F), 50 Ohm
2
SIM card slot with ejection button
3
LED “net” (green): Status indicator for net‐
work/cloud
4
LED “IoT” (red): Status indicator for data
transmission
5
Mini-USB socket − not used
6
Ethernet connection for user-end LAN
7
Ethernet connection for service purposes
only
8
Ethernet connection for
SIGMA CONTROL 2
9
24 V DC power supply
10
QR code
3.2.3 Technical specifications
Type
Characteristic
Value
Electrical data
Rated voltage [V]
24 +/− 10%
Rated current [A]
0.15
Continued run time in case of
power outage [s]
10
Mechanical data
Height x width x length [mm]
45 x 70 x 70
Mass [kg]
0.125
Mounting
Top hat rail 35 mm
Protection class
IP20 (IEC 529)
Material
Plastics
Conformity
CE: 2014/53/EU (Radio Equipment Directive - RED)
Mobile communication equipment: EN301511 v12.5.1;
EN301908 v13.1.1
EMC: EN 301489-1 v2.2.0 General Section; EN 301489-52
v0.0.7; DIN EN 61326-1 - 2018-09
Security: DIN EN 61010-1:2020-03; VDE 0411-1:2020-03
3
Technical Specifications
3.2
KAESER i.Box
No.: 9_9450 12 E
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X