Message
Possible cause
Remedy
0040W
Surge arrester
Overvoltage in the power supply
(Canadian version only)
Check power supply
Contact an authorised service
partner.
0045 W
DO test active
Test operation for manual actuation of
individual outputs is active.
Contact an authorised service
partner.
0050 W
Greasing system
Relubrication device fault
Contact an authorised service
partner.
0058 W
SC2 <=> SC2
communication error
Electrical connection interrupted.
IP configuration incorrect.
Check electrical connection.
Check IP configuration.
0074 A
External message 2
1)
0075 W
External message 3
1)
0080 W
Vibration monitoring
VSE ⇞
Alarm from vibration monitoring
Check operating conditions
0081 W
Vibration monitoring
VSE ↑
Warning from vibration monitoring
Check operating conditions
0082 W
Vibration monitoring sum
signal ↑
High vibration values
Contact an authorised service
partner.
0092 W
Switch p1
1)
0093 W
Switch p2
1)
0094 W
Switch T1
1)
0095 W
Switch T2
1)
0096 W
Switch block speed
1)
0097 W
SAM 4.0 communication
error
Bus link via SIGMA NETWORK inter‐
rupted.
Check bus lines and bus con‐
nector.
0098 W
Switch T3
1)
0099 W
Switch T_S
1)
0100 W
FC service mode
activated
User-supplied frequency converter in
service mode
Deactivate service mode in
10.1.1.3 menu
0200 W
Change lube h ↑
Lubricating oil:
Maintenance interval expired.
Change the lubricating oil.
10 Fault Recognition and Rectification
10.3 Interpreting warning messages
No.: 901700 14 E
Service Manual Controller
SIGMA CONTROL 2 BLOWER ≥ 4.0.X
163