13. Press the «Up» key.
The check box is activated.
14. Press «Enter».
Result The network is restarted.
The set network parameters are active.
8.2.15 Setting the e-mail function
SIGMA CONTROL 2 is able to send messages via e-mail. For this purpose, a network connection
with an SMTP server is required.
Setting e-mail parameters
Precondition Access level 2 is activated.
IP configuration is set; see chapter 8.2.14.
An SMTP server is active in the network.
The e-mail parameters are known. Request the required information from the IT department.
1. Open the 8.1.3
<Communication – Ethernet/SIGMA NETWORK – E-mail> menu.
2. Use «Up» or «Down» to select the
active: line.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
8.1.3 E-mail
Menu
active:
☐
Activating/deactivating the e-mail function
Blower number:
1
Language:
English GB
Setting the language
Repeat cut-off time:
5min
Use SSL:
☑
Encryption option
------------------------------
3. Press «Enter».
The check box
active: will flash.
4. Press «Up».
The check box is deactivated.
5. Press «Enter».
The e-mail function is deactivated.
8
Initial Start-up
8.2
Setting the controller
64
Service Manual Controller
SIGMA CONTROL 2 BLOWER ≥ 4.0.X
No.: 901700 14 E