Activating/deactivating the "Automatic restart" function
Precondition Access level 2 is activated.
1. Open the 5.3
<Configuration – Restart> menu.
2. Use «Up» or «Down» to select the
Automatic restart line.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.3 Restart
Menu
Automatic restart
☐
Automatic restart is deactivated
Delay
10 s
Set/expiring delay time
3. Press «Enter».
The setting mode is active.
4. Press the «Up» key.
The check box is activated.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.3 Restart
Menu
Automatic restart
☑
Active line with deactivated check box
Delay
10 s
Set/expiring delay time
5. Press the «Enter» key.
The setting is applied.
Result The "Automatic restart" function is activated.
8.5.4 Controlling the machine remotely
If the machine is to be shut down and switched on remotely, enter the following settings:
Overview
■ Activate option
Blower on
■ Set the load signal to remote operation
■ Set the idle signal to remote operation
■ If required, activate the «Time control» key and configure the time programme (see Chap‐
■ Activating the remote control
■ Press the «ON» key. The
ON LED illuminates green.
Two methods are available for starting the machine remotely:
8
Initial Start-up
8.5
Machine start and machine stop
88
Service Manual Controller
SIGMA CONTROL 2 BLOWER ≥ 4.0.X
No.: 901700 14 E