6. Press the «Enter» key.
The menu 5.4.4
Flow rate controlis displayed.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.4.4 Flow rate control
Menu
v_min
0.7 m³/min
v_max
4.3 m³/min
------------------------------
local set value
3.0 m³/min
Set value source
Local
Active line
7. Use the «Up» or «Down» keys to select the
Set value source line.
8. Press the «Down» key.
9. Press the «Enter» key.
The indicator flashes for the setpoint source currently selected.
10. Use the «Up» or «Down» key to select the desired setpoint source.
11. Press the «Enter» key.
The setting is applied accordingly.
12. Press the «Enter» key.
13. Using the «Up» or «Down» key, select the line
Reference.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.4.4 Flow rate control
Menu
local set value
m³/min
Set value source
Local
------------------------------
Reference
Intake conditions
Active line
14. Press the «Down» key.
15. Press the «Enter» key.
The indicator flashes for the reference currently selected.
16. Use the «Up» or «Down» key to select the desired reference.
17. Press the «Enter» key.
The setting is applied accordingly.
8.6.8 SFC acceleration time
In frequency-controlled machines, you can set the change speed for the speed in the
Fixed speed
and
External speed control operating modes. This will prevent pressure peaks caused by an ex‐
cessively fast acceleration of the speed.
Ramp up time is the time from minimum speed to reaching the machine-specific maximum speed.
The values for
Ramp up time and Ramp down time: which can be set at SIGMA CONTROL 2
are added to the similar parameters that have already been set in the FC.