Code Meaning
Remedy
See
chapter
Where can I get help?
Specialized
workshop
Kaeser
service
3201 Warning - OST pressure
high.
Have checked.
–
–
X
SW = specialized workshop; KS = KAESER SERVICE
ADT = Airend discharge temperature; OST - Oil separator cartridge
Tab. 59 Warning messages and measures relating to the compressor
Alarm codes, range 3300 – 3399 “controller warnings”
Code Meaning
Remedy
See
chapter
Where can I get help?
Specialized
workshop
Kaeser
service
3303 Warning - PLC tempera‐
ture high.
Check operating condi‐
tions.
Allow the machine to cool
down.
–
–
3313 Warning - HMI tempera‐
ture high.
Check operating condi‐
tions.
Allow the machine to cool
down.
–
–
SW = specialized workshop; KS = KAESER SERVICE
PLC - Programmable logic controller; HMI = Human-machine interface
Tab. 60 General warning messages and measures
9.3 Evaluating engine faults and alarms
Further information The engine service manual gives further information.
Possible cause
Remedy
Where can I get help?
SW
KS
Press the «QUICK STOP» but‐
ton.
Unlatch the «QUICK STOP»
–
–
Defective starter.
Have changed.
X
–
Engine electrical fault
Have repaired/changed.
X
–
Fuel tank empty.
Fill up the fuel tank
–
–
Airlock in the fuel line between
fuel tank and injector pump.
Bleed the fuel line (see chap‐
–
–
Fuel filter clogged.
Clean or replace, see chap‐
–
–
Fuel line broken.
Have changed.
X
–
SW = specialised workshop; KS = KAESER SERVICE
9
Fault Recognition and Rectification
9.3
Evaluating engine faults and alarms
No.: 901765 05 USE
Operator Manual Screw Compressor
M114 SIGMA CONTROL SMART