➤ Attach the following notice on the instrument panel to inform of the decommissioning measures
taken.
Attention!
1. The machine is decommissioned.
2. It is filled with preserving oil.
3. For recommissioning:
■ Take measures for recommissioning the compressor after a long period of storage.
■ Recommission according to service manual.
Date / signature
Tab. 88 Text for the long-term decommissioned and storage information notice
➤ Store in a dry place with constant temperatures.
12.2 Transport
Precondition Machine switched off and locked off
(«battery isolating switch» off)
The machine is fully vented, the pressure gauge reads 0 psig.
Machine is cooled down.
All compressed air consumers are disconnected.
All connecting lines and hoses disconnected and removed.
Any loose or movable parts that may fall when transporting are removed or secured.
12.2.1 Safety
Allow transportation only by personnel trained in safely dealing with motor vehicles and the
transporting of goods.
1.
There is danger of being run over or crushed by an overturning vehicle.
Death or serious injury can result from being crushed or run-over by a machine being towed.
➤ Riding on the machine while it is being towed is strictly forbidden.
2. Make sure the danger area is clear of personnel.
12.2.2 Towing the compressor on the road
The portable machine can be transported as trailer by a towing vehicle.
Machines without lighting system and service brake must not be towed on public roads.
Prerequisites for the towing on public roads:
■ Chassis with overrun brake
■ Lighting and signaling system.
All other machines may be transported only on non-public roads!
National and local regulations must be observed when towing the machine on public high‐
ways.
12 Decommissioning, Storage and Transport
12.2 Transport
226
Operator Manual Screw Compressor
M114 SIGMA CONTROL SMART
No.: 901765 05 USE