Feature
Value
PTC testing current [A]
(according to EN 50342)
640
Tab. 38 Batteries
2.7 Options
2.7.1 Air treatment options
2.7.1.1 Option ea, ec
Tool lubricator
Name
Temperature range [°F]
Fluid volume [gal]
Special road breaker lubricant
−25 ..... 50
2.5
Tab. 39 Road breaker lubricant recommendation
2.7.1.2 Option dc
Fresh air filter
Feature
Value
Maximum working pressure [psig]
16
Minimum ambient temperature [°F]
1.5
Maximum ambient temperature [°F]
30
Tab. 40 Fresh air filter conditions
2.7.1.3 Air quality at the compressed air outlets
Interrelation between compressed air treatment and compressed air quality:
Air Treatment
Compressed air quality
Option designation
Components
Characteristics
Abbreviation
da
■
After-cooler
■ Cyclone separator
cool and condensate-
free
A
da + db
■
After-cooler
■ Cyclone separator
■
Heat exchanger
dry and warmed
B
da + dd
■
After-cooler
■ Cyclone separator
■ Filter combination
dry and technically oil-
free
F
da + dd + db
■
After-cooler
■ Cyclone separator
■ Filter combination
■
Heat exchanger
technically oil-free and
warmed
G
2
Technical Data
2.7
Options
16
Operator Manual Screw Compressor
M114 SIGMA CONTROL SMART
No.: 901765 05 USE