6.5 Option od
Connecting the battery trickle charger
The battery charger is wired ready for operation and only needs to be connected to the user's pow‐
er supply.
The charger is factory set for use on a 400 V, 3-phase supply. For use with a 230 V, 1-phase
supply, the charger connections must be changed as shown in the electrical diagram in chap‐
Precondition The power supply disconnecting device is switched off,
the device is locked off,
a check has been made that no voltage is present.
1. Have the power supply connected only by authorized installation personnel or an authorized
electrician.
2. Take all safety precautions as required by Standards such as IEC 364 or EN 1012, part 1 and
EN 60204, part 1, as well as national safety regulations (BGV A3 in Germany). In addition, ob‐
serve the regulations of the local electricity supplier.
3. Select power supply cable conductor cross-sections and fusing in accordance with local regu‐
lations.
4.
Danger of fatal injury from electric shock!
➤ Switch off and lock out the power supply disconnecting device and check that no voltage is
present.
5. Connect the machine to the power supply.
Further information See chapter 2.7.3 for power supply specifications.
The electrical diagram in chapter 13.4.4 contains further details of the power supply connection.
6.6 Option rx
Installing a machine with stationary frame superstructure on a truck
platform
For safe footing, attach the machine frame with screw-in machine mounts on the load platform.
See the dimensional drawing in chapter 13.3 for position and dimensions of the machine mounts.
These machine mounts are either supplied with the machine or can be ordered separately from
KAESER.
Material Bolt-down machine feet (anti-vibration elements)
Fixing screws
Wrench
Precondition The machine is switched off.
Installing the machine mounts on the frame:
➤ Fasten the machine mounts (anti-vibration elements) at the frame:
Fasten the machine on the load platform:
Precondition The bolt-down machine mounts are attached to the machine.
6
Installation
6.5
Connecting the battery trickle charger
64
Operator Manual Screw Compressor
M114 SIGMA CONTROL SMART