1. Check the position of the air intake valve handle.
The pull wire is not yet completely drawn in: wait until the handle has automatically returned to
its original position.
The pull wire is completely drawn in. The machine can now be started.
2. Switch on the «battery isolating switch».
3. Start the machine.
8.7 Cleaning the machine after operation
Material High-pressure cleaner
Precondition The machine is switched off.
The machine has cooled down.
The machine is fully vented, the pressure gauge reads 0 psig.
All compressed air consumers are disconnected and the air outlet valves are open.
Maintain the following minimum distances to the object to be cleaned in order to prevent damages
to the machine when cleaning with the high-pressure cleaner.
■ Circular section jets: approximately 2.3 ft
■ Fan jets: approximately 1 ft
■ Dirt blasters: approximately 1 ft
Keep the water jet in permanent motion during the cleaning process. You prevent thus dam‐
age.
Cleaning with dry-ice jets is strictly forbidden as it could cause unforeseeable damages.
1.
Machine damage caused by strong water jet!
Direct water jets can damage or even destroy sensitive components.
➤ Do not directly focus a strong water jet towards sensitive components.
➤ Work carefully.
2. Carefully clean the machine with the high-pressure cleaner.
Water has accumulated in the sealed floor pan.
➤ Drain the water.
Catch the liquid and dispose in accordance with applicable environmental regulations.
Further information See chapter 10.9.7 for information to the draining of liquids within the machine.
8
Operation
8.7
Cleaning the machine after operation
No.: 901765 05 USE
Operator Manual Screw Compressor
M114 SIGMA CONTROL SMART
85