Fig. 34 Setting the tool lubricator
1
Shut-off valve
I – open
0 – closed
2
Metering knob
➤ Open the right-hand access door.
Adding lubricating oil
1. Open the shut-off valve.
2. Close the access door.
Setting the oil flow
The amount of oil the compressed air should contain depends on the application and must be de‐
termined by the user. It depends on the nature of the air consumers and the supply hoses.
The metering valve controls the flow of oil into the air.
■ Clockwise adjustment reduces the oil flow.
■ Counter-clockwise adjustmen: increases the oil flow.
1. Set the required oil flow.
2. Close the access door.
Further information Fill the tool lubricator with suitable oil (see chapter 10.15.1)
Shutting off lubricating oil
1. Close the shut-off valve.
2. Close the access door.
8
Operation
8.4
Operating the options
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART
89