Check in accordance with section: "Check safety shut-down at excessive airend discharge
temperature" in the separate operating manual for the SIGMA CONTROL MOBIL controller,
chapter “Have safety functions checked”.
Machine temperature
Value
Maximum airend discharge temperature
(automatic safety shut-down) [°F]
243
Tab. 100 Safety shut-down at excessive airend discharge temperature
➤ Have shut-down at excessive airend discharge temperature checked.
Result When the maximum airend discharge temperature is exceeded, the SIGMA CONTROL MOBIL
controller switches the machine off.
The machine does not shut down?
The excessive temperature shut-down function is no longer ensured.
➤ Immediately shut down the machine and cease any further operation.
➤ Have machine checked.
10.15 Maintenance for Optional Items
➤ Perform maintenance tasks according to the schedule in chapter 10.3.4.2.
10.15.1 Option ea, ec
Tool lubricator maintenance
Material Tool oil (special lubricant for road breakers),
Funnel
Cleaning cloths
Precondition The machine is switched off.
The machine is standing level.
The machine is fully vented, the pressure gauge reads 0 psig.
The machine has cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
10 Maintenance
10.15 Maintenance for Optional Items
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART
167