Operating mode Automatic cut-in
Continuous load
Switch position Position 1
Position 2
Engine speed
Electrical power consumption > 100 VA:
automatic maximum speed
Permanent maximum speed (en‐
gine under full load)
Power consumption below minimum value:
Engine run-on time of approximately 2 mi‐
nutes at maximum speed
Advantages
Fuel saving
Constant oscillation between maximum and
minimum speed avoided
Continuous generator power
available without delay
Tab. 64 Generator operating modes
4.8.5.2 Operating controls
The switches, fuses and outlet sockets for electrical consumers are located on the generator con‐
trol box. Individual consumers are connected only by these outlet sockets.
Generator 400/230 V/3~; 13 kVA:
Fig. 15 Instrument panel – generator control box, 400 V three phase
1
«Mode selector switch»
2
Power socket 400 V / 3 / N / PE
3
Power sockets 230 V AC/1/N/PE
4
Generator control box
5
«Generator main switch»
6
«Safety cut-out»
(with shunt opening release)
4
Design and Function
4.8
Options
No.: 901783 08 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M82 SIGMA CONTROL SMART
59