![background image](http://html1.mh-extra.com/html/kaeser/aircenter-sx-3/aircenter-sx-3_service-manual_3173165075.webp)
Fig. 32 Topping up the Cooling Oil
1
Hose coupling (air cooler venting)
2
Pressure gauge
3
Hose coupling (oil separator tank venting)
4
Oil filler with plug
5
Cooling oil level indicator
6
Male hose coupling/fitting
7
Shut-off valve.
A
Shut-off valve open
B
Shut-off valve closed
8
Maintenance hose
1. Vent the machine as described in 10.13.1.
2. Fill with cooling oil and test run as described in 10.13.2.
10.13.1 Venting the Machine (depressurizing)
The oil circuit vents automatically as soon as the machine is stopped.
Venting takes place in three stages:
■ Isolate the compressor from the compressed air system.
■ Vent air from the oil separator tank.
■ Vent air manually from the air cooler.
WARNING
Compressed air!
Compressed air and devices under pressure can injure or cause death if the contained energy is
released suddenly or uncontrolled.
➤ Vent all pressurized components and chambers completely.
Isolate the machine from the compressed air system
➤ Close the user's shut-off valve between the machine and the compressed air system.
If no shut-off valve is provided, the complete compressed air system must be vented.