Component:
Task
Daily
A250
A500
A1000
A1500
A2000
A3000
A36000
See chapter
Note
Other maintenance tasks
Check all accessible screw fit‐
tings, pipes and clamps for wear
and tightness.
X
KS , FW
Check hoses for proper seating,
leaks and wear.
X
KS , FW
Have hose lines replaced.
X
KS , FW
Check that all electrical connec‐
tions are tight.
X
KS , FW
Check the lighting system's
function.
X
KS ≙ contact KAESER SERVICE,
FW ≙ contact specialised workshop
Tab. 90 Regular machine maintenance tasks
10.2.3.2 Maintenance schedule for options
➤ Carry out maintenance tasks according to the following schedule.
Option:
Task
Daily
A250
A500
A1000
A2000
A20000
See chapter
Note
Option ec - tool lubricator:
Check the level in the tool lubri‐
cator.
X
Option da, db, dc, dd – cyclone separator:
Clean and check the dirt trap.
X
Options da, db, dc, dd – compressed air aftercooler:
Clean the cooler.
X
Option dd – filter combination:
Drain condensate.
X
Change the filter elements.
X
Option dc – fresh air filter:setting dimension:
Drain condensate.
X
Check the oil indicator.
X
Change the filter elements.
X
KS ≙ Contact KAESER SERVICE,
FW ≙ Contact specialised workshop,
EF ≙ Contact qualified electrician
10 Maintenance
10.2 Following the maintenance plans
96
Operator manual Portable compressor
M 64
No.: 9_5898 26 E
RAMIRENT