Fig. 68 Fresh air filter maintenance
1
Fresh air filter
2
Upper housing
3
Upper element (adsorption element)
4
Body
5
Lower filter element (high capacity ele‐
ment)
6
Lower housing
7
Condensate drain (tap for manual draining)
0 - closed
I - open
8
Oil indicator
➤ Open both doors.
10.7.4.1 Draining condensate
Material Receptacle
Cleaning cloth
1. Place the receptacle below the fresh air filter condensate drain point.
2. Open the condensate drain valve.
3. Close the doors.
4. Switch the machine on and run it in IDLE mode for approx. 2 minutes.
The condensate collecting in the filter housings is blown out.
5. Shut down the machine.
6. Open both doors.
7. Close the drain valve.
8. Carefully remove the receptacle.
9. Close the doors.
Condensate must be stored in suitable containers and disposed of in accordance with local
environmental regulations.