Type
Generator
400V, 3-ph
Generator
230V, 3-ph
Generator
115V, 2-phase
Power sockets
Quantity:
16 A; 230 V/3~/PE
–
1
–
32 A; 115 V/2~/PE
–
–
1
16 A; 115 V/2~/PE
–
–
2
Tab. 48 Connection sockets
Overload protection switch
Type
Generator
400V, 3-ph
Generator
230V, 3-ph
Generator
115V, 2-phase
Miniature circuit breaker
[A]
Quantity:
16
1
1
2
32
–
1
1
Tab. 49 Circuit breaker
Operating limits:
(to EN 60034-22, page 10, table)
Features
Value
Design category
G3
Voltage adjustment range [%]
±5
Static voltage deviation [%]
1
Maximum dynamic voltage drop [%]
–15
Maximum dynamic voltage rise [%]
20
Maximum voltage settling time [ms]
1500
Maximum voltage asymmetry [%]
1
Tab. 50 Generator operating limits
Maximum power loading by consumers
Resistive consumers include lamps and heaters, for example.
Electric motors and transformers are inductive consumers.
Nominal rating conditions:
■ Ambient temperature: 25 °C
■ Max. height above sea level at the place of use: 1000 m
2
Technical Specifications
2.8
Options
No.: 9_5898 26 E
Operator manual Portable compressor
M 64
19
RAMIRENT