Overload protection switch
Type
Generator
250V, 2-phase
Generator
125V, 1-phase
Miniature circuit breaker
[A]
Quantity:
20
1
1
Tab. 57 Circuit breaker
Operating limits:
(to EN 60034-22, page 10, table)
Features
Value
Design category
G3
Voltage adjustment range [%]
±5
Static voltage deviation [%]
1
Maximum dynamic voltage drop [%]
–15
Maximum dynamic voltage rise [%]
20
Maximum voltage settling time [ms]
1500
Maximum voltage asymmetry [%]
1
Tab. 58 Generator operating limits
Maximum power loading by consumers
Resistive consumers include lamps and heaters, for example.
Electric motors and transformers are inductive consumers.
Nominal rating conditions:
■ Ambient temperature: 25 °C
■ Max. height above MSL of the place of installation: 1,000 m
Generator [kVA]
13.0
8.0
Resistive consum‐
ers [kVA]
per phase
6.5
4.0
total
13.0
8.0
Inductive consumers [kW] Rated power
5.0
5.0
Tab. 59 Maximum power supply load
Power reduction at elevated ambient temperatures:
Ambient temperature
[°C]
Generator power
≤30
Full power available
>30
Reduction of 10 % for each temperature rise of 10 °C.
Tab. 60 Power reduction at elevated ambient temperatures
2
Technical Specifications
2.8
Options
22
Operator manual Portable compressor
M 64
No.: 9_5898 26 E
RAMIRENT