4. Check the housing gasket.
When damaged, replace the housing gasket.
5. Insert a new filter element.
Wear gloves!
6. Screw on the upper housing clockwise.
Change the oil indicator:
1. Unscrew the oil indicator.
2. Clean the housing and sealing surface with a lint-free cloth.
3. Screw in the new oil indicator.
Making operational:
1. Close the drain valve.
2. Reconnect the negative battery terminal.
3. Close the doors.
Dispose of old parts and contaminated materials according to environmental regulations.
Further information Further information on changing elements can be found in the operating instructions for pressur‐
ised air filters (fresh air filters) in chapter 13.7.
Starting the machine and performing a test run:
1. Switch the machine on and run it in IDLE mode for approx. 5 minutes.
2. Shut down the machine.
3. Wait until the machine has automatically vented.
Pressure gauge reads 0 bar.
4. Open the outlet valves.
5. Open both doors.
6. Check the fresh air filter housing and hose line for leaks.
7. Close the doors.
10.7.5 Option bc
Frost protector maintenance
At temperatures below 5°C, the level of antifreeze in the protector must be checked daily before
starting the compressor.