10.9.3 Option dc
Breathing air filter maintenance
When working on the breathing air filter, follow the Operating instructions for compressed air filter
(breathing air filter) given in chapter 13.16.
Precondition The machine is shut down.
The machine is standing level.
The machine is fully vented, the pressure gauge reads 0 bar.
All compressed air consumers are disconnected and the air outlet valves are open.
Fig. 80 Breathing air filter maintenance
1
Breathing air filter
2
Lower housing
3
Lower filter element (high capacity element)
4
Body
5
Upper element (adsorption element)
6
Upper housing
7
Condensate drain with manual opening tap
➤ Open the right-hand access door.
10.9.3.1 Draining condensate
Material Receptacle
Cleaning cloths
1. Place the receptacle below the breathing air filter condensate drain point.
2. Open the breathing air filter drain tap.
3. Close the access door.
4. Start up the compressor and run in idle for about 2 minutes..
The condensate collecting in the filter housings is blown out.
5. Shut down the machine.
6. Open the right-hand access door.
7. Close the drain tap.
8. Carefully remove the receptacle.
9. Close the access door.
Condensate must be stored in suitable containers and disposed of in accordance with local
environmental regulations.