➤ Press either «LEFT» or «RIGHT» .
This immediately selects the output setting menu.
Entry via menu structure
Precondition LOAD
<Main menu => engine operating data – compressor> selected.
Enter the output pressure in the sub-menu "set pressure in oil separator tank"
Fig. 43 Select menu option "set pressure in the oil separator tank"
1a
Main menu
2b
Compressor unit data
3
Navigation (menu)
1. Select the compressor data symbol and confirm with «Enter» .
2. Select menu option "set pressure in the oil separator tank"
This immediately selects the output setting menu.
Set pressure:
The pressure can only be set at lower than the nominal working pressure of the machine.
A pressure setting 1.5 bar higher than nominal is possible with the appropriate password. This
can only be temporary and falls back to nominal if no key is pressed for 3 minutes or if the
controller is switched off.
Fig. 44 Setting the output pressure
4
Select menu option "set pressure in the oil
separator tank"
5
Minimum working pressure (lower setting
limit)
6
Setting scale with indicator bar
7
Maximum working pressure (upper setting
limit)
8
Current setting
8
Operation
8.2
Starting and stopping
78
Service Manual Screw Compressor
M135 SIGMA CONTROL MOBIL
No.: 9_6975 00 E