Feature
Value
PTC testing current [A]
(according to EN 50342)
480
Tab. 32 Battery
Further information Depending on machine equipment, a higher capacity battery may be required. See chapter 2.7.2
for low temperature equipment.
2.7 Options
2.7.1 Option ea
Tool lubricator
Name
Temperature range [°C]
Fluid volume [l]
Special road breaker lubricant
−25 – 50
2,5
Tab. 33 Road breaker lubricant recommendation
2.7.2 Option ba, bb
Low temperature equipment
2.7.2.1 Ambient conditions
Positioning
Limit value
Maximum altitude AMSL* [m]
1000
Minimum ambient temperature [°C]
−25
Maximum ambient temperature [°C]
50
* Higher altitudes are permissible only after consultation with the manufacturer.
Tab. 34 Ambient conditions
2.7.2.2 Option ba
Air lines frost protection
Antifreeze
Fluid volume [l]
Wabcothyl
0,3
Tab. 35 Antifreeze recommendation
2.7.2.3 Option bb
Coolant pre-heating
Coolant pre-heater
Value
Model
DEFA A411120
Voltage [V]
230
Power [W]
600
Tab. 36 Coolant pre-heater