9.3.5 Too much oil residue in the compressed air
Possible cause
Remedy
Where can I get help?
Specialised
workshop
KAESER Ser‐
vice
Oil separator cartridge scavenge
line clogged.
Clean the strainer in the separa‐
tor cartridge dirt trap or have
changed if necessary.
–
X
Fractured oil separator car‐
tridge.
Change, see chapter 10.4.5.
–
–
Oil level in the oil separator tank
too high.
Reduce to maximum level, see
chapters 10.4.1 and 10.4.3.
–
–
Tab. 53 Fault: too much oil residue in the compressed air
9.3.6 Oil flows from the compressor air filter after shutdown
Possible cause
Remedy
Where can I get help?
Specialised
workshop
KAESER Ser‐
vice
Defective non-return function of
the inlet valve.
Repair or have replaced if nec‐
essary.
–
X
Tab. 54 Fault: oil flows from the compressor air filter after shutdown
9
Fault Recognition and Rectification
9.3
Compressor faults and alarms
66
Service Manual Screw Compressor
M43
No.: 9_9432 02 E
RAMIRENT