Material Wrench
Cleaning cloths
Precondition The machine is shut down.
The machine is standing level.
The machine is fully vented, the pressure gauge reads 0 bar.
All compressed air consumers are disconnected and the air outlet valves are open.
Fig. 32 Checking cooling oil level
1
Oil separator tank
2
Oil filler port
3
Screw plug
A
Mark for
minimum oil level
B
Mark for
maximum oil level
1. Slowly unscrew and withdraw the plug
3
from the oil filler port.
2. Check that oil is visible.
Top up if no oil is visible.
3. Replace the filler plug
3
.
10.4.2 Topping up the cooling oil
Material Cooling oil
Funnel
Wrench
Cleaning cloths
Precondition The machine is shut down.
The machine is standing level.
The machine is fully vented, the pressure gauge reads 0 bar.
Machine cooled down.
All compressed air consumers are disconnected and the air outlet valves are open.
The negative cable to the battery is disconnected.
Filling with cooling oil
A sticker on the oil separator tank specifies the type of oil used.
10 Maintenance
10.4 Compressor
88
Service Manual Screw Compressor
M43
No.: 9_9432 02 E
RAMIRENT