Operation
8 --- 37
8.6.5
Full -- load/Idle sequence occurs too frequently (short cycles)
Possible cause:
Remedy:
Receiver tank size is too small or there
is no tank.
Consult authorized KAESER distributor
for recommended tank size.
Diameter of hose connecting the unit
to the receiver tank is too small.
Connecting hose diameter should not
be smaller than the air discharge pipe
diameter. Install larger hose if neces-
sary.
Minimum pressure check valve leaks.
Check the valve and replace defective
parts.
Flow is restricted at discharge.
Look for plugged filters, partially
closed valves, frozen pipes or malfunc-
tioning pressure regulators.
8.6.6
Safety relief valve blows off
Possible cause:
Remedy:
System does not discharge at idle.
Make sure ball valve in vent line is
open. Check the control lines, inlet
valve and combined control/vent valve.
Replace defective parts as needed.
Oil separator cartridge is contamina-
ted.
Check the cartridge pressure differen-
tial and replace cartridge if necessary.
Minimum pressure check valve does
not open.
Check the valve for blockage and re-
place defective parts as necessary.
Safety relief valve not properly sized
for the pressure of the compressor
unit.
Check blow ---off pressure and com-
pare to name plate of the compressor.
Replace if necessary.
8.6.7
Oil in the package
Possible cause:
Remedy:
Maintenance hose or coupling still
plugged into the air receiver connec-
tion point.
Remove hose/coupling from the con-
nection point.
Pressure relief valve blowing off.
see chapter 8.6.6.
Oil running out of air filter.
see chapter 8.6.4.
Air receiver hose coupling loose.
Tighten up hose coupling or replace
as necessary.
Oil cooler leaking.
Have the oil cooler replaced by an au-
thorized KAESER Service Technician.
8.6.8
Excessive oil consumption
Possible cause:
Remedy:
Wrong oil is being used in the unit.
Replace with correct oil type.
Consult authorized KAESER distributor
for other oil types not listed.
Oil separator cartridge has ruptured.
Check pressure differential and re-
place oil separator cartridge if neces-
sary.
Summary of Contents for SK 19
Page 10: ...Technical Specification 1 6 ...
Page 19: ...Construction and Operation 5 15 ...
Page 20: ...Construction and Operation 5 16 ...
Page 64: ...Appendix 11 60 11 Appendix 11 1 Wiring Diagram ...
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ...Appendix 11 77 11 2 Spare Parts List ...
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......