Escaping oil mist is damaging to health.
➤ Do not direct the maintenance hose at persons while venting.
➤ Do not inhale the oil mist.
Isolating the machine from the air system
➤ Close the user's shut-off valve between the machine and the air distribution network.
If no shut-off valve is provided by the user, the complete air distribution network must be ven‐
ted.
Venting the oil separator tank
The oil circulation vents automatically as soon as the machine is stopped.
➤ Check that the oil separator tank pressure gauge reads 0 psig.
The pressure gauge does not read 0 psig after automatic venting?
➤ Make sure that the user's shut-off valve is closed or that the complete air system is ven‐
ted.
➤ With the shut-off valve closed, insert the male hose fitting
6
into the hose coupling
3
.
➤ Slowly open the shut-off valve
7
to release pressure.
➤ Disconnect the male hose fitting
6
and close the shut-off valve
7
.
➤ If manual venting does not bring the oil separator tank pressure gauge to zero: Contact
an authorized KAESER service representative.
Manually venting the air cooler
After shutting down the compressor and venting the oil separator tank, the machine is still un‐
der pressure from the air system or the section from the shut-off valve to the minimum pres‐
sure/check valve.
1. With the shut-off valve closed, insert the male hose fitting
6
into the hose coupling
1
.
2. Slowly open the shut-off valve
7
to release pressure.
3. Disconnect the male hose fitting
6
and close the shut-off valve
7
.
10.15.2 Topping off with cooling oil and trial run
Replenishing the cooling oil
A sticker on the oil separator tank specifies the type of oil used.
1.
Compressed air!
Compressed air and devices under pressure can injure or cause death if the contained energy
is released suddenly.
➤ De-pressurize all pressurized components and enclosures.
2.
The machine could be damaged by unsuitable oil!
➤ Never mix different types of oil.
➤ Never top off with a different type of oil than has already been used in the machine.
3. Slowly unscrew the filler plug
4
.
10 Maintenance
10.15 Replenishing the cooling oil
68
Operator Manual Screw Compressor
SM Tri-Voltage, SIGMA CONTROL 2
9_5875 33 USE