Initial Start
7 --- 22
If the insertion key (3) at the door interlock is incorrectly aligned, inad-
vertent shutdown of the compressor package can occur.
The insertion key (3) align with the door interlock switch (1) without
binding against the sides of the interlock switch when the maintenance
door is closed.
If necessary, re---align the insertion key (3).
Loosen the bolts (4).
Align the insertion dey (3) so that it glides smoothly into the interlock switch (1).
If necessary, use washers to help align the insertion key (3) with the interlock
switch (1).
Tighten the bolts (4) again.
1
4
4
3
2
2
6
5
1 Door interlock switch
4
Bolt
2 Clamping nut
5
Frame
3 Insertion key
6
Maintenance door
Functional check of the interlock switch
A functional check of the door interlock switch must be made after in-
itial start.
Start the compressor package (see chapter 8.3).
Open the left ---hand maintenance door --- the compressor package will shut down im-
mediately if the door interlock switch functions correctly.
Close the left ---hand maintenance door.
Reset the alarm message by pressing the acknowledge (reset) key (11, see
chapter 8.2.1) on SIGMA CONTROL.
The compressor package is now ready to start again.
Attention!
Attention!
Summary of Contents for SM 8
Page 9: ...Technical Specification 1 6...
Page 16: ...Construction and Operation 5 13...
Page 17: ...Construction and Operation 5 14...
Page 54: ...Appendix 11 51 11 Appendix 11 1 Wiring Diagram...
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 74: ...SM 8 SM 11 A 08 B 07 C 14 D 11...
Page 76: ......
Page 78: ......
Page 80: ......
Page 82: ......