Kahlenberg 

Instructions, M-522, Software Rev. R., Rev. 10/7/2019 

 

 

Page 2 of 10 

Main Power M-522 Controller, A.C. 100-240 VAC 50/60Hz (Terminals 1 and 2) 

Emergency Power M-522 Controller, D.C. 8-30 VDC (Terminals 3 and 4) 

Main Power for Morse Light:  110-240VAC 

OR

 24 VDC  (Terminals 23 and 24) 

 

POWER OUTPUTS: 

Output Forward Horn: 110-240 VAC  (Terminals 5 and 6) 

Output Aft Horn: 110-240 VAC  (Terminals 7 and 8) 

Output Forward Horn: 24 VDC  (Terminals 9 and 10)  

Output Aft Horn: 24 VDC  (Terminals 11 and 12) 

Output Morse Light: 110-240 VAC or 24VDC (Terminals 25 and 26) 

 

**NOTE: 24 Volt output to horns will only function when main A.C. input to controller is not connected, 

or is interrupted in the case of A.C. mains failure on board. 

 

External Switch Connections (Relays using External 24 Volt D.C. Power Source):   

External At-Will Push Buttons, Horns (1) (Terminal 30) 

External Morse Key or Momentary Push button, Morse Light (1) (Terminal 31) 

External General Emergency Alarm Push Button or External GEA Input (1)  (Terminal 32) 

External Abandon Ship Push Button (1) (Terminal 33) 

PA Interrupt (1) (Terminal 34) 

External Momentary Pushbutton for Automated Horn Signals (1) (Terminal 29) 

Negative D.C. Connection, External 24 VDC Power, (1) (Terminals 35, 36) 

 

Additional Contact Closure Connections: 

 

General Emergency Alarm:  Output for GEA Signal from M-522 for relay connection to other external 

sound/light devices, (Terminals 19 and 20) 

 

Sound Surveillance System:  Normally Open Contacts close upon M-522 activation of horn, bell, or gong, 

for connection to mute external Sound Surveillance System, (Terminals 21 and 22) 

 

Other Connections: 

 

CAN (Control Area Network) (CAN 2.0A, 29 bit identifiers) Connection to connect additional 

M-522 Controllers (Terminals 37-39)   Note:  If CAN connection is utilized to wire only M-522s 

to each other, external of a properly configured CAN bus, a 120 Ohm resistor must be wired in 

parallel as a jumper between terminals 37 and 38 (CAN HIGH and CAN LOW) on each 

networked M-522 to provide resistance on this circuit. 

 

 

2.)

 

INSTALLATION

 -  

 

WARNING:  HIGH VOLTAGE MAY BE PRESENT INSIDE ENCLOSURES.  BE SURE 

TO SHUT OFF POWER, TAG OUT, AND VERIFY NO VOLTAGE IS PRESENT 

BEFORE INSTALLING OR ATTEMPTING TO SERVICE THIS UNIT.  FAILURE TO 

FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH. 

 

 

 

Summary of Contents for M-522

Page 1: ...operated in conjunction with external Sound Surveillance Systems and or Public Address systems Multiple M 522 units can be utilized on the vessel and will communicate with each other in cases where mu...

Page 2: ...Terminal 33 PA Interrupt 1 Terminal 34 External Momentary Pushbutton for Automated Horn Signals 1 Terminal 29 Negative D C Connection External 24 VDC Power 1 Terminals 35 36 Additional Contact Closur...

Page 3: ...e in conjunction with the M 522 such as external General Alarm Systems Setting SW1 Switches On the internal circuit board of the M 522 there is a switch assembly labeled SW1 Settings on this switch as...

Page 4: ...ther or not the M 522 Controller will allow the aft and forward horn to sound simultaneously Per IMO Rules where two ship whistles are installed a distance greater than 100M apart they must not be sou...

Page 5: ...uld be connected per Drg 3 6749 utilizing shielded cables and wire gauge per electrical requirements as given below Power Source Required 100 240 Volt A C 50 60 Hz 1 Ph AND OR 8 30 Volts D C Electrica...

Page 6: ...s IMO COLREGS RULE 35 These automated signals are controlled by the row of buttons directly beneath the ships graphic on the faceplate as shown below Automatic On Off The Automatic On Off button start...

Page 7: ...ows per IMO COLREGS RULE 35 One Prolonged Signal______________________Making Way through Water Underway Two Prolonged Signals____ Underway But Stopped and making no way through the water One Prolonged...

Page 8: ...Drg 3 6749 for connection locations These external push buttons make contact for 24 Volts to the M 522 input from a remote power source An optional 100 240 VAC to 24 VDC power supply model M 800 is a...

Page 9: ...f installed on the vessel See Drg 3 6749 for connection location 4 CARE AND MAINTENANCE The M 522 Sound and Light Control is a solid state device designed to provide many years of maintenance free ope...

Page 10: ...e 10 of 10 5 DRAWING REFERENCES Outline Dimensions 3 6728 Parts List 3 6729 Wiring Diagrams 3 6749 General or as Specified by Contract Kahlenberg Industries Inc 1700 12th St P O Box 358 Two Rivers WI...

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ...n Active Auto Code Red LED Timer 120 Seconds Timer 90 Seconds Timer 60 Seconds Timer 40 Seconds Code 1 LED Byte 3 Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Code 2 LED Code 3 LED Code 4 LED Code...

Page 15: ...tion Message Number Time Offset ms Bus Type ID hex Reserved Data Length Code Data Bytes hex FWD HORN 171 5383 214 1 Rx 00000002 00 8 02 00 00 00 00 00 00 00 172 5408 895 1 Rx 00000001 00 8 01 00 08 00...

Reviews: