TROUBLESHOOTING
IF THE COMPRESSOR DOES NOT SHUT OFF AFTER
APPROXIMATELY 5 MINUTES OR IF IT SHUTS OFF BUT
INTERMITTENTLY TRIES TO START UP (CHUGS),
IMMEDIATELY DISCONNECT POWER AND CHECK THE
FOLLOWING:
•
VERIFY THE CURRENT AND WIRE SIZE (SEE ABOVE
SUGGESTED WIRE SIZES) GOING TO THE COMPRESSOR.
NOTE: THE 12-VOLT MOTOR REQUIRES 21 AMPS AT FULL
LOAD.
•
CHECK THE SYSTEM FOR AIR LEAKS, AND CHECK THAT
THE DRAIN COCK ON THE TANK IS COMPLETELY CLOSED.
•
MAKE SURE THE V-69K SOLENOID VALVE (IF SUPPLIED)
IS ORIENTATED PROPERLY. THE “1” STAMPED ON THE
BRASS BODY OF THE VALVE RECEIVES THE AIR FROM
THE COMPRESSOR/TANK AND THE OUTLET STAMPED
“2” IS CONNECTED TO THE HORN.
•
IF THE COMPRESSOR DOES NOT OPERATE AT ALL, VERIFY
CURRENT SUPPLY, AND VERIFY THAT THE LEVER SWITCH
ON THE SIDE OF THE PRESSURE SWITCH (BLACK BOX ON
TOP OF COMPRESSOR PUMP) IS SET TO AUTO.
•