PaGE 11
KrP PrEP taBlEs
FIG. 10
DEFrost
tIME clocK
Pan cHIllEr
tEMPEraturE
control
rEFrIGEratED BasE
tEMPEraturE
control
6. PrEstart cHEcKs
(cont.)
6E - tEMPEraturE control sEttInGs
(contInuED)
:
On all remote units and earlier self-contained models, the temperature control is located
inside the lower storage cabinet. (See Fig. 10)
On both self-contained and remote units, the temperature control marked “Pan Chiller”
should be set at 23°F with a 3°F differential. The operating display range should read
between 20°F and 28°F. Temperature control marked “Base Refrigerator” should be set
at 37°F with a 3°F differential. This display should read between 34°F and 40°F. The
temperature control settings are “locked” to avoid unauthorized adjustments. Therefore,
adjustments to the set point must be made by an authorized service technician.
If a freezer base, temperature control marked “Base Freezer” should be set at 0°F with
2°F differential. Temperature display should read between –2°F and 2°F.